OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
335916003 0215600 2012-08-15 242-02 61 ST AVENUE, BAYSIDE, NY, 11361
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-08-15
Emphasis L: FALL
Case Closed 2015-02-06

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 2013-02-11
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2013-02-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard: a) On or about August 15, 2012-Job Site at 242-02 61 St Avenue Bayside, NY 11361 Employee on the roof pulling HVAC wire exposed to falls of 12-feet. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100333 B02
Issuance Date 2013-02-11
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2013-02-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2): On or about August 15, 2012-Job Site at 242-02 61 St Avenue Bayside, NY 11361 a) Employee pulling HVAC control wire through an open 220 volt panel did not lock out both power switches. WRITTEN ABATEMENT DOCUMENTATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.