Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
335916003 | 0215600 | 2012-08-15 | 242-02 61 ST AVENUE, BAYSIDE, NY, 11361 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100023 C01 |
Issuance Date | 2013-02-11 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-02-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard: a) On or about August 15, 2012-Job Site at 242-02 61 St Avenue Bayside, NY 11361 Employee on the roof pulling HVAC wire exposed to falls of 12-feet. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100333 B02 |
Issuance Date | 2013-02-11 |
Current Penalty | 0.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-02-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2): On or about August 15, 2012-Job Site at 242-02 61 St Avenue Bayside, NY 11361 a) Employee pulling HVAC control wire through an open 220 volt panel did not lock out both power switches. WRITTEN ABATEMENT DOCUMENTATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |