340885201
|
0216000
|
2015-08-28
|
54 NARDOZZI PLACE, NEW ROCHELLE, NY, 10805
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-08-28
|
Case Closed |
2015-08-28
|
Related Activity
Type |
Inspection |
Activity Nr |
1044827 |
Health |
Yes |
|
|
340448273
|
0216000
|
2015-03-03
|
54 NARDOZZI PLACE, NEW ROCHELLE, NY, 10805
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-03-03
|
Case Closed |
2015-10-13
|
Related Activity
Type |
Complaint |
Activity Nr |
965952 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1065229 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100101 B |
Issuance Date |
2015-05-29 |
Abatement Due Date |
2015-06-05 |
Current Penalty |
1040.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-06-22 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: Location: Shop a) Compressed gas cylinders of oxygen and acetylene were stored next to each other; on or about 4/14/15 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100157 G02 |
Issuance Date |
2015-05-29 |
Current Penalty |
1040.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-06-22 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter. Location: Shop a) Employees are instructed to put out small incipient stage fires and the employer did not provide fire extinguisher training; on or about 3/4/15. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100141 D02 II |
Issuance Date |
2015-05-29 |
Abatement Due Date |
2015-07-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-06-22 |
Nr Instances |
1 |
Nr Exposed |
15 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water. Location: Bathrooms a) Bathrooms were not provided with hot water; on or about 3/3/15. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 H03 IV |
Issuance Date |
2015-05-29 |
Abatement Due Date |
2015-07-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-06-22 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(3)(iv): The employer did not train employees regarding the new label elements and safety data sheets format. Location: Workplace a) Where employees use hazardous chemicals, including but not limited to acetone, n-Hexane and toluene , the employer failed to provide information and training on the new Globally Harmonized System to employees; on or about 03-3-2015. |
|
|
340652296
|
0216000
|
2015-03-03
|
54 NARDOZZI PLACE, NEW ROCHELLE, NY, 10805
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-03-03
|
Case Closed |
2018-02-21
|
Related Activity
Type |
Complaint |
Activity Nr |
965952 |
Health |
Yes |
|
Type |
Referral |
Activity Nr |
987199 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1044827 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2015-05-29 |
Abatement Due Date |
2015-06-10 |
Current Penalty |
1440.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-06-22 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Automotive shop a) The bench grinder (Black & Decker model 1766, 3450 RPMs) had the tool rest adjusted at a distance of one fourth of an inch to the abrasive wheel; on or about 04-14-2015. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2015-05-29 |
Abatement Due Date |
2015-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-06-22 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Automotive shop a) The bench grinder (Black & Decker model 1766, 3450 RPMs) had the tongue guard adjusted at a distance of one inch to the abrasive wheel; on or about 04-14-2015. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2015-05-29 |
Abatement Due Date |
2015-06-10 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-06-22 |
Nr Instances |
2 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Automotive shop a) An electrical extension cord used by employees to power a "Wagner" heat gun and other power tools had an open ground connection; on or about 04-14-2015. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2015-05-29 |
Abatement Due Date |
2015-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-06-22 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Automotive shop a) An electrical breakers panel box had an unused and unguarded knock-out opening; on or about 04-14-2015. |
|
|
110606894
|
0216000
|
1996-10-02
|
54 NARDOZZI PLACE, NEW ROCHELLE, NY, 10805
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
1996-10-02
|
Case Closed |
1997-03-21
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100106 E06 II |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-04 |
Current Penalty |
455.0 |
Initial Penalty |
455.0 |
Nr Instances |
1 |
Nr Exposed |
36 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100107 C06 |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-03-04 |
Current Penalty |
455.0 |
Initial Penalty |
455.0 |
Nr Instances |
1 |
Nr Exposed |
36 |
Gravity |
02 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-04 |
Current Penalty |
455.0 |
Initial Penalty |
455.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100147 C05 I |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-09 |
Current Penalty |
340.0 |
Initial Penalty |
340.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-04 |
Current Penalty |
340.0 |
Initial Penalty |
340.0 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-04 |
Current Penalty |
455.0 |
Initial Penalty |
455.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040002 A |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-04 |
Nr Instances |
1 |
Nr Exposed |
36 |
Gravity |
00 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100023 C01 |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-07 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
01 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100157 G02 |
Issuance Date |
1997-01-30 |
Abatement Due Date |
1997-02-04 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
01 |
|
|
109873547
|
0216000
|
1993-07-22
|
54 NARDOZZI PLACE, NEW ROCHELLE, NY, 10805
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1993-07-23
|
Case Closed |
1993-10-14
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19040006 |
Issuance Date |
1993-09-16 |
Abatement Due Date |
1993-10-19 |
Current Penalty |
1050.0 |
Initial Penalty |
1050.0 |
Nr Instances |
5 |
Nr Exposed |
21 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100020 G02 |
Issuance Date |
1993-09-16 |
Abatement Due Date |
1993-10-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
00 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
1993-09-16 |
Abatement Due Date |
1993-10-19 |
Nr Instances |
10 |
Nr Exposed |
10 |
Gravity |
00 |
|
|