Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-03-31
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2015-11-20
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2015-04-14 |
Abatement Due Date |
2015-05-17 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Contest Date |
2015-05-07 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) At the jobsite, on the scaffold, on or about 3/31/15: Employees were working on a pump jack scaffold that was not erected and used under the direction of a competent person. Abatement certification must be submitted for these items. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2015-04-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-05-07 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a) At the jobsite, on the scaffold, on or about 3/31/15: Employees were working on a pump jack scaffold approximately 15 feet from grade where workers were not provided appropriate access to the roof surface that was approximately 3 feet above the working surface of the scaffold. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 |
Issuance Date |
2015-04-14 |
Abatement Due Date |
2015-04-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-05-07 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph. a) At the jobsite, on the scaffold, on or about 3/31/15: Employees were working on a pump jack scaffold approximately 15 feet from grade where a horizontal life line was connected to the scaffold not designed for that equipment. Abatement certification must be submitted for these items. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2015-04-14 |
Abatement Due Date |
2015-04-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-05-07 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) At the jobsite, on the scaffold, on or about 3/31/15: Employees were working on a pump jack scaffold approximately 15 feet from grade where the scaffold ends were not protected with guardrails. Abatement certification must be submitted for these items. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2015-04-14 |
Abatement Due Date |
2015-04-22 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Contest Date |
2015-05-07 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite, on the roof, on or about 3/31/15: Employees were working on a 5:12 pitch roof with a ground to eave height of approximately 20 feet without fall protection. Abatement certification must be submitted for this item. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260502 D15 II |
Issuance Date |
2015-04-14 |
Abatement Due Date |
2015-05-17 |
Current Penalty |
1500.0 |
Initial Penalty |
2800.0 |
Contest Date |
2015-05-07 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, and not installed under the supervision of a qualified person. a) At the jobsite, on the roof, on or about 3/31/15: 2 employees were working on a 5:12 pitch roof with a ground to eave height of approximately 20 feet while being connected to the same anchor point. A third line was connected to the same anchor point that was not being used when observed. Abatement certification must be submitted for this item. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260502 D06 III |
Issuance Date |
2015-04-14 |
Abatement Due Date |
2015-04-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-05-07 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(6)(iii): A snaphook was engaged to a Dee-ring to which another snaphook or other connector is attached and to any objectwhich is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. a) At the jobsite, on the roof, on or about 3/31/15: 2 employees were working on a 5:12 pitch roof with a ground to eave height of approximately 20 feet while being connected to the same anchor point. A third line was connected to the same anchor point that was not being used when observed. Abatement certification must be submitted for this item. |
|
|