Search icon

MAZZEO HOME IMPROVEMENT SPECIALISTS, LLC

Company Details

Name: MAZZEO HOME IMPROVEMENT SPECIALISTS, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 06 Mar 2012 (13 years ago)
Entity Number: 4212064
ZIP code: 13148
County: Seneca
Place of Formation: New York
Address: 3161 EAST BAYARD STREET EXT, SENECA FALLS, NY, United States, 13148

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 3161 EAST BAYARD STREET EXT, SENECA FALLS, NY, United States, 13148

Filings

Filing Number Date Filed Type Effective Date
120626000815 2012-06-26 CERTIFICATE OF PUBLICATION 2012-06-26
120306000006 2012-03-06 ARTICLES OF ORGANIZATION 2012-03-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340505213 0215800 2015-03-31 RIVER KNOLL BUILDING 27, BALDWINSVILLE, NY, 13027
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2015-03-31
Emphasis L: FALL, P: FALL
Case Closed 2015-11-20

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2015-04-14
Abatement Due Date 2015-05-17
Current Penalty 0.0
Initial Penalty 2800.0
Contest Date 2015-05-07
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) At the jobsite, on the scaffold, on or about 3/31/15: Employees were working on a pump jack scaffold that was not erected and used under the direction of a competent person. Abatement certification must be submitted for these items.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2015-04-14
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-05-07
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a) At the jobsite, on the scaffold, on or about 3/31/15: Employees were working on a pump jack scaffold approximately 15 feet from grade where workers were not provided appropriate access to the roof surface that was approximately 3 feet above the working surface of the scaffold.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 G04
Issuance Date 2015-04-14
Abatement Due Date 2015-04-22
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-05-07
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph. a) At the jobsite, on the scaffold, on or about 3/31/15: Employees were working on a pump jack scaffold approximately 15 feet from grade where a horizontal life line was connected to the scaffold not designed for that equipment. Abatement certification must be submitted for these items.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2015-04-14
Abatement Due Date 2015-04-22
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-05-07
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) At the jobsite, on the scaffold, on or about 3/31/15: Employees were working on a pump jack scaffold approximately 15 feet from grade where the scaffold ends were not protected with guardrails. Abatement certification must be submitted for these items.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-04-14
Abatement Due Date 2015-04-22
Current Penalty 0.0
Initial Penalty 2800.0
Contest Date 2015-05-07
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite, on the roof, on or about 3/31/15: Employees were working on a 5:12 pitch roof with a ground to eave height of approximately 20 feet without fall protection. Abatement certification must be submitted for this item.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260502 D15 II
Issuance Date 2015-04-14
Abatement Due Date 2015-05-17
Current Penalty 1500.0
Initial Penalty 2800.0
Contest Date 2015-05-07
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, and not installed under the supervision of a qualified person. a) At the jobsite, on the roof, on or about 3/31/15: 2 employees were working on a 5:12 pitch roof with a ground to eave height of approximately 20 feet while being connected to the same anchor point. A third line was connected to the same anchor point that was not being used when observed. Abatement certification must be submitted for this item.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260502 D06 III
Issuance Date 2015-04-14
Abatement Due Date 2015-04-22
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-05-07
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(6)(iii): A snaphook was engaged to a Dee-ring to which another snaphook or other connector is attached and to any objectwhich is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. a) At the jobsite, on the roof, on or about 3/31/15: 2 employees were working on a 5:12 pitch roof with a ground to eave height of approximately 20 feet while being connected to the same anchor point. A third line was connected to the same anchor point that was not being used when observed. Abatement certification must be submitted for this item.

Date of last update: 09 Mar 2025

Sources: New York Secretary of State