Search icon

WRM DRYWALL, INC.

Company Details

Name: WRM DRYWALL, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 09 Mar 2012 (13 years ago)
Entity Number: 4214648
ZIP code: 11368
County: Queens
Place of Formation: New York
Address: 106-04 CORONA AVENUE, CORONA, NY, United States, 11368

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
C/O ATAX 0007-ADOLF MANAGEMENT CORP. DOS Process Agent 106-04 CORONA AVENUE, CORONA, NY, United States, 11368

Filings

Filing Number Date Filed Type Effective Date
120309000779 2012-03-09 CERTIFICATE OF INCORPORATION 2012-03-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339879488 0215000 2014-07-31 40 WEST 57TH STREET, NEW YORK, NY, 10019
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2014-07-31
Emphasis L: FALL
Case Closed 2019-08-05

Related Activity

Type Referral
Activity Nr 913406
Safety Yes
Type Inspection
Activity Nr 987433
Safety Yes
Type Inspection
Activity Nr 987565
Safety Yes
Type Inspection
Activity Nr 987568
Safety Yes
Type Inspection
Activity Nr 987573
Safety Yes
Type Inspection
Activity Nr 987579
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 A02 II E
Issuance Date 2014-11-25
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-12-22
Nr Instances 11
Nr Exposed 8
Related Event Code (REC) Accident
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: LOCATION: 18th floor, 40 West 57th Street. TMG Project On or about July 31, 2014. a) Employees working throughout the project were exposed to electric shock hazards because the incandescent light bulbs used for temporary illumination were not protected from impact by materials or equipment.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260452 W02
Issuance Date 2014-11-25
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-12-22
Nr Instances 1
Nr Exposed 18
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold was used in a stationary manner: Location: 40 West 57th Street, New York, NY, 18th Floor On or about July 31, 2014 A). An employee was working on a portable, Baker type scaffold, the scaffold tipped and the employee fell to the floor. The scaffold casters were not locked to prevent the sudden rolling of the scaffold.

Date of last update: 26 Mar 2025