Search icon

HAMPTON DWELL CORP.

Company Details

Name: HAMPTON DWELL CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 15 Mar 2012 (13 years ago)
Entity Number: 4217535
ZIP code: 11963
County: Suffolk
Place of Formation: New York
Address: P.O. BOX 2948, SAG HARBOR, NY, United States, 11963

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent P.O. BOX 2948, SAG HARBOR, NY, United States, 11963

Filings

Filing Number Date Filed Type Effective Date
120315000752 2012-03-15 CERTIFICATE OF INCORPORATION 2012-03-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339972705 0214700 2014-09-29 6 SUNSET RD, SAG HARBOR, NY, 11963
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2014-09-29
Emphasis L: FALL
Case Closed 2019-11-19

Related Activity

Type Referral
Activity Nr 911314
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-09-30
Abatement Due Date 2014-10-06
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-11-04
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) Worksite, South: Employees were working on a ladder jack scaffold. No means of fall protection was used; on, or about, 09/29/2014. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260452 K05
Issuance Date 2014-09-30
Abatement Due Date 2014-10-06
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-11-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(5): Scaffold platforms shall not be bridged one to another. a) Worksite, South: Scaffold platforms were being bridged one to another; on, or about, 09/29/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2014-09-30
Abatement Due Date 2014-10-10
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-11-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Worksite, South: Employees were working on a scaffold without having received training on relative hazards; on, or about, 09/29/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2014-09-30
Abatement Due Date 2014-10-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite: Employees were working on the roof of a residential home. Employees were not protected from fall hazards and were not trained to recognize such hazards; on, or about, 09/29/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-09-30
Abatement Due Date 2014-10-06
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-11-04
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite: Employees were working the roof of a residential home without having protection from fall hazards; on, or about, 09/29/2014. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2014-09-30
Abatement Due Date 2014-10-06
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-11-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Worksite, North: An employee was using two sections of a 40 foot extension ladder separately to access higher levels; on, or about, 09/29/2014. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261053 B12
Issuance Date 2014-09-30
Abatement Due Date 2014-10-06
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-11-04
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails: a) Worksite, West: Employees used a metal ladder to access the second floor of a residential home. The ladder was positioned directly adjacent to live power lines; on, or about, 09/29/2014. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01007
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2014-09-30
Abatement Due Date 2014-10-10
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2014-11-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: a) Worksite, North: An employee was using two sections of a 40 foot extension ladder separately to access higher levels. Employees did not receive training so that they could recognized associated hazards; on, or about, 09/29/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State