347348617
|
0215000
|
2024-03-14
|
714 39TH STREET, BROOKLYN, NY, 11232
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-03-14
|
Case Closed |
2024-09-09
|
Related Activity
Type |
Inspection |
Activity Nr |
1346332 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1734869 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1734866 |
Safety |
Yes |
|
|
343463329
|
0215000
|
2018-09-12
|
714 39TH STREET, BROOKLYN, NY, 11232
|
|
Inspection Type |
Fat/Cat
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-09-12
|
Emphasis |
N: SVEP, N: TRENCH
|
Related Activity
Type |
Accident |
Activity Nr |
1381600 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 K02 |
Issuance Date |
2019-03-12 |
Abatement Due Date |
2019-03-22 |
Current Penalty |
5304.0 |
Initial Penalty |
5304.0 |
Contest Date |
2019-03-28 |
Final Order |
2023-08-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety. Location: a) Inside the excavation of the jobsite at 714 39th Street Brooklyn NY: On or about 09/12/2018, competent person was informed of a potential cave in hazard, and did not take action to protect employees that were working in the excavation. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 I02 |
Issuance Date |
2019-03-12 |
Abatement Due Date |
2019-03-18 |
Current Penalty |
5304.0 |
Initial Penalty |
5304.0 |
Contest Date |
2019-03-28 |
Final Order |
2023-08-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(i)(2): Excavation below the level of the base or footing of any foundation or retaining wall that could be reasonably expected to pose a hazard to the employees was not prohibited, where the none of the requirements of (i)(2)(i), (i)(2)(ii), (i)(2)(iii), (i)(2)(iv) were met. Location: a) Inside the excavation by the foundation wall on the west side of the jobsite: On or about 09/12/2018, The employer excavated below the footing and did not adequately underpin and brace. Employees were not prohibited from working next to the excavation wall. |
|
Citation ID |
02001 |
Citaton Type |
Willful |
Standard Cited |
19260652 C |
Issuance Date |
2019-03-12 |
Abatement Due Date |
2019-03-18 |
Current Penalty |
53039.0 |
Initial Penalty |
53039.0 |
Contest Date |
2019-03-28 |
Final Order |
2023-08-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(c): Designs of support systems shield systems, and other protective systems selected and constructed by the employer or his designee were not in accordance with the requirements of paragraph (c)(1); or in the alternative, paragraph (c)(2); or in the alternative, paragraph (c)(3); or in the alternative, paragraph (c)(4). Location: a) Inside the excavation by the foundation wall on the west side of the jobsite: On or about 09/12/2018, employees were working in an excavation with an inadequate protective system that was not constructed based on appropriate designs in accordance with the requirements of 1926.652(c). |
|
|
343247094
|
0215000
|
2018-06-21
|
718 39TH STREET, BROOKLYN, NY, 11232
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-06-21
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260403 I02 I |
Issuance Date |
2018-07-25 |
Current Penalty |
3696.0 |
Initial Penalty |
3696.0 |
Final Order |
2018-11-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. Location: a) Inside the excavation at southeast side of the job site: On or about 06/21/18, there was a live electrical panel where the circuit breakers openings were not covered. An employee was exposed to electric shock hazard. |
|
|