Filing Number Date Filed Type Effective Date
120417000836 2012-04-17 CERTIFICATE OF INCORPORATION 2012-04-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346877376 0214700 2023-08-02 884 JERICHO TURNPIKE, WOODBURY, NY, 11797
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2023-08-02
Emphasis N: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1687729
Safety Yes
Type Inspection
Activity Nr 1687735
Safety Yes
Type Inspection
Activity Nr 1687732
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2023-08-21
Abatement Due Date 2023-08-25
Current Penalty 3349.0
Initial Penalty 3349.0
Final Order 2023-09-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about August 2, 2023, at 884 Jericho Turnpike, Woodbury 11797, employees working from a pump jack scaffold to install siding on a two-story residential building, that had a support leg resting directly on soil, without a base plate or mud sill. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2023-08-21
Abatement Due Date 2023-08-25
Current Penalty 3349.0
Initial Penalty 3349.0
Final Order 2023-09-25
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii):Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On or about August 2, 2023, at 884 Jericho Turnpike, Woodbury NY 11797, on the north side of a two story residential building, employees were installing siding while working from a pump Jack scaffold, approximately 15 feet above the ground, without a means of fall protection. b) On or about August 2, 2023, at 884 Jericho Turnpike, Woodbury NY 11797, on the east side of a two story residential building, employees were installing siding while working from a pump Jack scaffold, approximately 20 feet above the ground, without a means of fall protection. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260452 J02
Issuance Date 2023-08-21
Abatement Due Date 2023-08-25
Current Penalty 3349.0
Initial Penalty 3349.0
Final Order 2023-09-25
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(2):Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) On or about August 2, 2023, at 884 Jericho Turnpike, Woodbury 11797, employees were working from a pump jack scaffold to install siding on the east side of a two-story residential building. The bottom of the support poles did not have triangular support braces and was not secured to the structure. b) On or about August 2, 2023, at 884 Jericho Turnpike, Woodbury 11797, employees were working from a pump jack scaffold to install siding on the north side of a two-story residential building. The bottom of the support poles did not have triangular support braces and was not secured to the structure. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B06
Issuance Date 2023-08-21
Abatement Due Date 2023-08-25
Current Penalty 3349.0
Initial Penalty 3349.0
Final Order 2023-09-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(6):Unsecured ladder(s) were used on surfaces that were not stable and level: a) On or about August 2, 2023, at 884 Jericho Turnpike, Woodbury NY 11797, employees were installing siding on a two-story residential building, while working from a pump jack scaffold. The access ladder for this scaffold was set up on a sloped surface with loose and uneven soil. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.