Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338232622 | 0215800 | 2013-01-04 | 100 RACHEL CARSON WAY TURQUOISE #10, ITHACA, NY, 14850 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-02-15 |
Abatement Due Date | 2013-02-28 |
Current Penalty | 250.0 |
Initial Penalty | 2800.0 |
Contest Date | 2013-03-05 |
Final Order | 2013-08-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were installing framing material on the roof of a two story building without the use of personal fall protection. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260304 H01 |
Issuance Date | 2013-02-15 |
Abatement Due Date | 2013-02-28 |
Current Penalty | 250.0 |
Initial Penalty | 2800.0 |
Contest Date | 2013-03-05 |
Final Order | 2013-08-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a table saw that was not guarded by a hood. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260304 G01 |
Issuance Date | 2013-02-15 |
Abatement Due Date | 2013-02-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2013-03-05 |
Final Order | 2013-08-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(g)(1): The sides of the lower blade were not guarded to the full diameter of the blade by a device that would automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a compound miter saw that was not equipped with a guard that automatically adjusted itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection the full diameter of the blade. |
Citation ID | 01002C |
Citaton Type | Serious |
Standard Cited | 19260304 F |
Issuance Date | 2013-02-15 |
Abatement Due Date | 2013-02-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2013-03-05 |
Final Order | 2013-08-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a table saw that was not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator. |
Citation ID | 01002D |
Citaton Type | Serious |
Standard Cited | 19260304 F |
Issuance Date | 2013-02-15 |
Abatement Due Date | 2013-02-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2013-03-05 |
Final Order | 2013-08-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(f): Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers on dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a table saw that did not have non-kickback fingers on dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260403 B01 |
Issuance Date | 2013-02-15 |
Abatement Due Date | 2013-02-28 |
Current Penalty | 0.0 |
Initial Penalty | 1530.0 |
Contest Date | 2013-03-05 |
Final Order | 2013-08-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a compound miter saw that had a damaged external trigger guard housing exposing employees to electrical shock while engaging the operating switch. |