120806000303 2012-08-06 CERTIFICATE OF PUBLICATION 2012-08-06
120423000609 2012-04-23 ARTICLES OF ORGANIZATION 2012-04-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338232622 0215800 2013-01-04 100 RACHEL CARSON WAY TURQUOISE #10, ITHACA, NY, 14850
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-01-04
Emphasis L: FALL, P: FALL
Case Closed 2013-10-22

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-02-15
Abatement Due Date 2013-02-28
Current Penalty 250.0
Initial Penalty 2800.0
Contest Date 2013-03-05
Final Order 2013-08-26
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were installing framing material on the roof of a two story building without the use of personal fall protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260304 H01
Issuance Date 2013-02-15
Abatement Due Date 2013-02-28
Current Penalty 250.0
Initial Penalty 2800.0
Contest Date 2013-03-05
Final Order 2013-08-26
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a table saw that was not guarded by a hood.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260304 G01
Issuance Date 2013-02-15
Abatement Due Date 2013-02-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-03-05
Final Order 2013-08-26
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(g)(1): The sides of the lower blade were not guarded to the full diameter of the blade by a device that would automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a compound miter saw that was not equipped with a guard that automatically adjusted itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection the full diameter of the blade.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260304 F
Issuance Date 2013-02-15
Abatement Due Date 2013-02-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-03-05
Final Order 2013-08-26
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a table saw that was not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260304 F
Issuance Date 2013-02-15
Abatement Due Date 2013-02-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-03-05
Final Order 2013-08-26
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(f): Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers on dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a table saw that did not have non-kickback fingers on dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260403 B01
Issuance Date 2013-02-15
Abatement Due Date 2013-02-28
Current Penalty 0.0
Initial Penalty 1530.0
Contest Date 2013-03-05
Final Order 2013-08-26
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a) 100 Rachel Carson Way Turquois #10 - On or about 4 January, 2013 - Employees were using a compound miter saw that had a damaged external trigger guard housing exposing employees to electrical shock while engaging the operating switch.