Search icon

THE RENOVATORS MASTERS OF DISASTERS LLC

Company Details

Name: THE RENOVATORS MASTERS OF DISASTERS LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 04 May 2012 (13 years ago)
Entity Number: 4240642
ZIP code: 14424
County: Ontario
Place of Formation: New York
Address: 5993 CTY RD 32, CANANDAIGUA, NY, United States, 14424

DOS Process Agent

Name Role Address
THE RENOVATORS MASTERS OF DISASTERS LLC DOS Process Agent 5993 CTY RD 32, CANANDAIGUA, NY, United States, 14424

History

Start date End date Type Value
2012-05-04 2014-05-27 Address 4028 ROUTE 5 AND 20, CANANDAIGUA, NY, 14424, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
200519060074 2020-05-19 BIENNIAL STATEMENT 2020-05-01
180511006198 2018-05-11 BIENNIAL STATEMENT 2018-05-01
160614006525 2016-06-14 BIENNIAL STATEMENT 2016-05-01
140527006252 2014-05-27 BIENNIAL STATEMENT 2014-05-01
120830000445 2012-08-30 CERTIFICATE OF PUBLICATION 2012-08-30
120504000053 2012-05-04 ARTICLES OF ORGANIZATION 2012-05-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339636169 0215800 2014-03-18 205 LAKESHORE DRIVE, CANANDAIGUA, NY, 14424
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2014-03-18
Emphasis L: FALL
Case Closed 2017-01-31

Related Activity

Type Complaint
Activity Nr 877270
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2014-03-27
Abatement Due Date 2014-04-11
Current Penalty 500.0
Initial Penalty 2800.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Entire worksite, on or about 3-18-14: Two employees were performing various construction tasks without the training necessary for the employees to recognize the hazards associated with their work.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2014-03-27
Abatement Due Date 2014-04-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) Center of building, inside trusses, on or about 3-18-14: Two employees were performing demolition work tasks while standing on the 1-1/2 inch wide bottom chords of wood trusses, exposing the employees to a fall hazard of 14 feet 5 inches. b) East and west sides of building, top of wall, on or about 3-18-14: Two employees were walking/working on the 6 inch wide top plate of a wall, exposing the employees to a fall hazard of 14 feet 5 inches.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-03-27
Abatement Due Date 2014-04-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Center of building, inside trusses, on or about 3-18-14: Two employees were performing demolition work tasks while standing on the 1-1/2 inch wide bottom chords of wood trusses, without fall protection, exposing the employees to a fall hazard of 14 feet 5 inches. b) East and west sides of building, top of wall, on or about 3-18-14: Two employees were walking/working on the 6 inch wide top plate of a wall, without fall protection, exposing the employees to a fall hazard of 14 feet 5 inches.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260025 A
Issuance Date 2014-03-27
Abatement Due Date 2014-04-06
Current Penalty 250.0
Initial Penalty 1200.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures and scrap lumber with protruding nails was not kept clear from work areas: a) Entire worksite, on or about 3-18-14: Two employees were demolishing a building while walking on and around large quantities of demolition debris, with nails protruding from boards.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260150 C01 I
Issuance Date 2014-03-27
Abatement Due Date 2014-04-06
Current Penalty 500.0
Initial Penalty 1600.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof, and the travel distance from any point of the protected area to the nearest fire extinguisher exceeded 100 feet: a) Entire worksite, on or about 3-18-14: Two employees were demolishing a 14, 500 square foot building with the nearest fire extinguisher being located in a basement and the entry stairs blocked by debris.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260150 C01 VI
Issuance Date 2014-03-27
Abatement Due Date 2014-04-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite: a) North end of building, on or about 3-18-14: Two employees were refueling a generator with the nearest fire extinguisher being located in a basement and the entry stairs blocked by debris.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260850 A
Issuance Date 2014-03-27
Abatement Due Date 2014-04-06
Current Penalty 250.0
Initial Penalty 2000.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations: a) Entire worksite, on or about 3-18-14: Two employees were demolishing and structurally compromising a building, without an engineering survey by a competent person.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260850 B
Issuance Date 2014-03-27
Abatement Due Date 2014-04-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.850(b): The walls or floors were not shored or braced where employee(s) were required to work within a damaged structure to be demolished: a) Entire worksite, on or about 3-18-14: Two employees were demolishing a building without shoring damaged portions of the building to prevent collapse.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-03-27
Current Penalty 500.0
Initial Penalty 1600.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) North side of building, on or about 3-18-14: Employees were accessing a roof area via an extension ladder that was extended 23 inches above the landing surface, exposing the employees to a fall hazard of 14 feet 5 inches.
Citation ID 02001
Citaton Type Other
Standard Cited 19260404 F06
Issuance Date 2014-03-27
Abatement Due Date 2014-04-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-17
Final Order 2014-08-27
Nr Instances 2
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) North side of building, on or about 3-18-14: Employees were operating hand held power tools that were plugged into a generator through two extension cords that did not have a continuous path to ground due to missing ground pins.
Citation ID 03001
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2014-12-17
Abatement Due Date 2015-02-10
Current Penalty 0.0
Initial Penalty 400.0
Final Order 2015-01-22
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) At the jobsite, on or about 12/17/2014: The employer did not provide abatement certification for Citation 1, Items 001a, 001b, 001c, 002, 003a, 003b, 004a, 004b, and Citation 2, Item 001 issued on March 27, 2014. An abatement demand letter was sent to the employer on October 7, 2014. Abatement certification is required for this item.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
3543538301 2021-01-22 0219 PPS 5993 County Road 32, Canandaigua, NY, 14424-9351
Loan Status Date 2022-03-05
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 38697
Loan Approval Amount (current) 38697
Undisbursed Amount 0
Franchise Name -
Lender Location ID 47007
Servicing Lender Name The Canandaigua National Bank and Trust Company
Servicing Lender Address 72 S Main St, CANANDAIGUA, NY, 14424-1905
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Canandaigua, ONTARIO, NY, 14424-9351
Project Congressional District NY-24
Number of Employees 4
NAICS code 236118
Borrower Race White
Borrower Ethnicity Not Hispanic or Latino
Business Type Limited Liability Company(LLC)
Originating Lender ID 47007
Originating Lender Name The Canandaigua National Bank and Trust Company
Originating Lender Address CANANDAIGUA, NY
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 39110.84
Forgiveness Paid Date 2022-02-23
6164277303 2020-04-30 0219 PPP 5993 COUNTY ROAD 32, CANANDAIGUA, NY, 14424
Loan Status Date 2021-02-05
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 38699.25
Loan Approval Amount (current) 38699.25
Undisbursed Amount 0
Franchise Name -
Lender Location ID 47007
Servicing Lender Name The Canandaigua National Bank and Trust Company
Servicing Lender Address 72 S Main St, CANANDAIGUA, NY, 14424-1905
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address CANANDAIGUA, ONTARIO, NY, 14424-0001
Project Congressional District NY-24
Number of Employees 5
NAICS code 236118
Borrower Race White
Borrower Ethnicity Not Hispanic or Latino
Business Type Limited Liability Company(LLC)
Originating Lender ID 47007
Originating Lender Name The Canandaigua National Bank and Trust Company
Originating Lender Address CANANDAIGUA, NY
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 38962.62
Forgiveness Paid Date 2021-01-07

Date of last update: 26 Mar 2025

Sources: New York Secretary of State