Name: | HOME EXTERIOR PROFESSIONALS LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 04 May 2012 (13 years ago) |
Entity Number: | 4240943 |
ZIP code: | 12180 |
County: | Rensselaer |
Place of Formation: | New York |
Address: | 39 SHERMAN AVE, TROY, NY, United States, 12180 |
Name | Role | Address |
---|---|---|
JASON SPIEGEL | DOS Process Agent | 39 SHERMAN AVE, TROY, NY, United States, 12180 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
120919001072 | 2012-09-19 | CERTIFICATE OF PUBLICATION | 2012-09-19 |
120504000530 | 2012-05-04 | ARTICLES OF ORGANIZATION | 2012-05-04 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
336652789 | 0213100 | 2012-10-02 | 301 ALTAMONT AVE., SCHENECTADY, NY, 12303 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2013-01-24 |
Abatement Due Date | 2013-02-01 |
Current Penalty | 1200.0 |
Initial Penalty | 2400.0 |
Final Order | 2013-03-08 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold 10 feet or more above a lower level shall be protected from falling to that lower level by the use of a personal fall arrest system or guardrail system: a) Jobsite, on or about 10/2/2012; employee was exposed to fall hazards of approximately 11 feet while measuring and installing vinyl siding and insulation and standing on a pump jack scaffold plank without fall protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-01-24 |
Current Penalty | 510.0 |
Initial Penalty | 1020.0 |
Final Order | 2013-03-08 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Jobsite, on or about 10/2/2012; Employees were exposed to fall hazards of approximately 10 feet while using a portable folding ladder to access the ladder jack scaffold plank and the porch overhang where materials were stored. |
Date of last update: 26 Mar 2025