Name: | SILVERCUP SCAFFOLDING 1 LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 07 May 2012 (13 years ago) |
Entity Number: | 4242012 |
ZIP code: | 11205 |
County: | Kings |
Place of Formation: | New York |
Address: | 146 SPENCER STREET SUITE 4002, BROOKLYN, NY, United States, 11205 |
Name | Role | Address |
---|---|---|
THE LLC | DOS Process Agent | 146 SPENCER STREET SUITE 4002, BROOKLYN, NY, United States, 11205 |
Name | Role |
---|---|
REGISTERED AGENT REVOKED | Agent |
Start date | End date | Type | Value |
---|---|---|---|
2012-05-07 | 2013-02-19 | Address | ONE COMMERCE PLAZA, 99 WASHINGTON AVE, SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Registered Agent) |
2012-05-07 | 2013-02-19 | Address | ONE COMMERCE PLAZA, 99 WASHINGTON AVE, SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
130219000471 | 2013-02-19 | CERTIFICATE OF CHANGE | 2013-02-19 |
130108001090 | 2013-01-08 | CERTIFICATE OF PUBLICATION | 2013-01-08 |
120507001001 | 2012-05-07 | ARTICLES OF ORGANIZATION | 2012-05-07 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339233439 | 0215000 | 2013-07-26 | 184 JORALEMON STREET, BROOKLYN, NY, 11205 | |||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 835333 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2013-11-26 |
Abatement Due Date | 2013-12-09 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2014-01-16 |
Nr Instances | 1 |
Nr Exposed | 9 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder shall not be used as a step. a) In front of jobsite, Employees used the top and top step of an A-frame stepladder as steps to climb onto and get down from a sidewalk shed for access to a supported scaffold tower. On or about 07/26/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |