Search icon

BETTER CONSTRUCTION SERVICES, LLC

Company Details

Name: BETTER CONSTRUCTION SERVICES, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 18 May 2012 (13 years ago)
Entity Number: 4247857
ZIP code: 12211
County: Albany
Place of Formation: New York
Address: 8 fernwood dr, ALBANY, NY, United States, 12211

DOS Process Agent

Name Role Address
BETTER ROOFS DOS Process Agent 8 fernwood dr, ALBANY, NY, United States, 12211

History

Start date End date Type Value
2012-05-18 2024-05-03 Address 3 HAMPTON ST, ALBANY, NY, 12209, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
240503000886 2024-05-03 BIENNIAL STATEMENT 2024-05-03
220325001067 2022-03-25 BIENNIAL STATEMENT 2020-05-01
120518001030 2012-05-18 ARTICLES OF ORGANIZATION 2012-05-18

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342497468 0213100 2017-07-25 132 GLEN AVENUE, SCOTIA, NY, 12302
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2017-07-25
Emphasis L: FALL
Case Closed 2017-10-31

Related Activity

Type Inspection
Activity Nr 1249427
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-08-21
Current Penalty 1600.0
Initial Penalty 2716.0
Final Order 2017-10-16
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Roof - On or about July 25, 2017, employees were performing roofing work on a 4 on 12 sloped roof, 24' in height, without the use of fall protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-08-21
Current Penalty 1600.0
Initial Penalty 2173.0
Final Order 2017-10-16
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a) Work site - On or about July 25, 2017, employees were accessing the roof with an extension ladder that only extended approximately 1.5' above the roof surface and was not secured to anything.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 A02 VIII
Issuance Date 2017-08-21
Abatement Due Date 2017-08-29
Current Penalty 0.0
Initial Penalty 305.0
Final Order 2017-10-16
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2)(viii): The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M: a) Roof - On or about July 25, 2017, employees were performing roofing work, exposed to fall hazards. Employees had been trained in fall hazards but the employer was not qualified in the fall protection standards.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State