Name: | REALITY ROOFING AND REMODELING INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 24 May 2012 (13 years ago) |
Entity Number: | 4249816 |
ZIP code: | 11501 |
County: | Nassau |
Place of Formation: | New York |
Address: | 23 ROSELLE STREET, MINEOLA, NY, United States, 11501 |
Contact Details
Phone +1 516-248-6592
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
ROBERT SHANNON | DOS Process Agent | 23 ROSELLE STREET, MINEOLA, NY, United States, 11501 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
1431496-DCA | Inactive | Business | 2012-05-25 | 2019-02-28 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
120524000302 | 2012-05-24 | CERTIFICATE OF INCORPORATION | 2012-05-24 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
2559808 | TRUSTFUNDHIC | INVOICED | 2017-02-23 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2559809 | RENEWAL | INVOICED | 2017-02-23 | 100 | Home Improvement Contractor License Renewal Fee |
1947755 | RENEWAL | INVOICED | 2015-01-23 | 100 | Home Improvement Contractor License Renewal Fee |
1947754 | TRUSTFUNDHIC | INVOICED | 2015-01-23 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
1147354 | TRUSTFUNDHIC | INVOICED | 2013-06-26 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
1228642 | RENEWAL | INVOICED | 2013-06-26 | 100 | Home Improvement Contractor License Renewal Fee |
1147355 | TRUSTFUNDHIC | INVOICED | 2012-05-25 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
1147357 | CNV_TFEE | INVOICED | 2012-05-25 | 6.849999904632568 | WT and WH - Transaction Fee |
1147356 | LICENSE | INVOICED | 2012-05-25 | 75 | Home Improvement Contractor License Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339184012 | 0214700 | 2013-07-12 | 26 JEROME AVENUE, MINEOLA, NY, 11501 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 953980 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2014-01-09 |
Current Penalty | 0.0 |
Initial Penalty | 2800.0 |
Final Order | 2014-01-29 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. (a) 26 Jerome Avenue, Mineola, NY (Worksite), south and southwest sides of residential home, first story roof - An employee was re-nailing the existing roof sheathing with a pneumatic nail gunn and was not provided with; or using eye protection, which exposed the employee to serious eye injuries on, or about July 12, 2013. (b) Worksite, north side of residential home, first story roof - Employees were re-nailing the existing roof sheathing with pneumatic nail guns and were not provided with; or using eye protection, which exposed them to serious eye injuries on, or about July 12, 2013. Note: Abatement for this violation was previously documented; therefore, the employer is not required to submit abatement certification or documentation for this violation in accordance with 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 B05 II |
Issuance Date | 2014-01-09 |
Abatement Due Date | 2014-01-15 |
Current Penalty | 0.0 |
Initial Penalty | 2400.0 |
Final Order | 2014-01-29 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end. (a) Worksite, west side of the residential home, ladder jack scaffold - Employees were installing 2" x 2" drip edge along the west edge of the first story roof from a ladder jack scaffold. The Werner 24' aluminum scaffold stage, Model # 2424, used to create the work platform was extended 8' beyond the south support and was not secured to prevent it from tipping, which exposed the employees to being struck-by scaffold components and a fall of 8' to the ground below on, or about July 12, 2013. Note:The employer is required to submit abatement certification for this violation in accordance with 29 CFR 1903.19. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2014-01-09 |
Abatement Due Date | 2014-01-29 |
Current Penalty | 0.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-01-29 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedures or controls to minimize those hazards. (a) Worksite, west side of residential home, ladder jack scaffold - Employees were installing 2" x 2" drip edge along the west edge of the first story roof from a ladder jack scaffold. The employees were not trained to work from scaffolds; and did not recognize the hazards, which were created by the Werner 24' aluminum scaffold stage, Model # 2424, being extended 8' beyond the south ladder jack bracket on, or about July 12, 2013. Note: The employer is required to submit abatement certification for this violation in accordance with 29 CFR 1903.19. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260454 B |
Issuance Date | 2014-01-09 |
Abatement Due Date | 2014-01-29 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-01-29 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. (a) Worksite, west side of residential home, ladder jack scaffold - Employees erected a ladder jack scaffold to perform roofing work on a residential home. The employees were not trained to erect, disassemble, move, repair, maintain, or inspect scaffolds; and did not recognize the hazards, which were created by the Werner 24' aluminum scaffold stage, Model # 2424, being extended 8' beyond the south ladder jack bracket on, or about July 12, 2013. Note: The employer is required to submit abatement certification for this violation in accordance with 29 CFR 1903.19. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2014-01-09 |
Abatement Due Date | 2014-01-15 |
Current Penalty | 0.0 |
Initial Penalty | 2800.0 |
Final Order | 2014-01-29 |
Nr Instances | 2 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Worksite, south side of the residential home, first story roof - Employees were engaged in re-roofing work on the first story of a residential home. The employees were working at a height of 11' on the 4:12 pitch roof and were wearing personal fall arrest harnesses, but did not have their lanyards connected to the rope stops on the vertical lifelines, which exposed the employees to a fall of 11' to the ground below on, or about July 12, 2013. (b) Worksite, north side of the residential home, first story roof - Employees were engaged in re-roofing work on the first story of a residential home. The employees were working at a height of 11' on the 4:12 pitch roof, without fall protection, which exposed the employees to a fall of 11' to the ground below on, or about July 12, 2013. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation in accordance with 29 CFR 1903.19. |