Name: | K SQUARE TOTAL STRUCTURE LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 17 Jul 2012 (13 years ago) |
Entity Number: | 4272090 |
ZIP code: | 10304 |
County: | Richmond |
Place of Formation: | New York |
Address: | 564 BAY STREET, STATEN ISLAND, NY, United States, 10304 |
Name | Role | Address |
---|---|---|
THE LLC | DOS Process Agent | 564 BAY STREET, STATEN ISLAND, NY, United States, 10304 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
120717000946 | 2012-07-17 | ARTICLES OF ORGANIZATION | 2012-07-17 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339091928 | 0215600 | 2013-05-30 | 136-33 37TH AVE, FLUSHING, NY, 11354 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 672818 |
Safety | Yes |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2012-10-04 |
Emphasis | N: TRENCH |
Case Closed | 2018-03-09 |
Related Activity
Type | Complaint |
Activity Nr | 602731 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B05 |
Issuance Date | 2012-12-14 |
Abatement Due Date | 2012-12-24 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-04-17 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(5): Each employee on the face of formwork or reinforcing steel was not protected from falling 6 feet (1.8 m) or more to lower levels by personal fall arrest systems, safety net systems, or positioning device systems: a). on or about 10/04/12, at the site of 136-33 37th Ave. Flushing, NY An employee reinforcing steel on an edge of the excavation was not protected from falling. The employee was exposed to the hazard of fall aproximately 16 ft. to the lower level. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260701 B |
Issuance Date | 2012-12-14 |
Abatement Due Date | 2012-12-24 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-04-17 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a). on or about 10/04/12, at the site of 136-33 37th Ave. Flushing, NY The employer did not ensure that the rebar were capped or bent. The employees were exposed to the hazard of impalement. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Date of last update: 26 Mar 2025
Sources: New York Secretary of State