OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341478469 0215000 2016-05-10 141 21ST ST., BROOKLYN, NY, 11232
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2016-05-10
Case Closed 2017-05-23

Related Activity

Type Referral
Activity Nr 1092110
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100024 H
Issuance Date 2016-09-12
Abatement Due Date 2016-09-22
Current Penalty 1873.0
Initial Penalty 2673.0
Final Order 2016-09-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms. a) 2nd floor stair landing in the center of workshop: Standard railings were not provided on the open sides of the exposed stair landing on the 2nd floor. On or about 05/09/16.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100037 A03
Issuance Date 2016-09-12
Abatement Due Date 2016-09-22
Current Penalty 1873.0
Initial Penalty 2673.0
Final Order 2016-09-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. a) 1st floor, metal stairway: Exit route from the 2nd floor to the entrance was not freed and unobstructed. The metal stairway, which is the only exit route from the 2nd floor, was obstructed by steel beams stored in front of the stairway. On or about 05/09/16.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100243 C01
Issuance Date 2016-09-12
Abatement Due Date 2016-09-22
Current Penalty 1854.0
Initial Penalty 2673.0
Final Order 2016-09-27
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4). a) 2nd floor workstation and 1st floor workstation: Employees used portable electric powered angle grinders to cut metal. The portable grinders were designed to accommodate a guard for the cutting wheel, and were not provided with such safety guards. On or about 05/09/16.