344040019
|
0215000
|
2019-04-25
|
835 REMSEN AVE, BROOKLYN, NY, 11236
|
|
Inspection Type |
FollowUp
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2019-04-25
|
Case Closed |
2019-06-03
|
Related Activity
Type |
Inspection |
Activity Nr |
1170901 |
Safety |
Yes |
|
|
344118252
|
0215000
|
2019-04-25
|
835 REMSEN AVE, BROOKLYN, NY, 11236
|
|
Inspection Type |
Complaint
|
Scope |
NoInspection
|
Safety/Health |
Health
|
Close Conference |
2019-04-25
|
Case Closed |
2019-07-01
|
Related Activity
Type |
Complaint |
Activity Nr |
1125948 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1171053 |
Health |
Yes |
|
|
341709012
|
0215000
|
2016-08-18
|
835 REMSEN AVE, BROOKLYN, NY, 11236
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-08-18
|
Case Closed |
2023-01-19
|
Related Activity
Type |
Complaint |
Activity Nr |
1125948 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1171053 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2016-12-13 |
Abatement Due Date |
2016-12-21 |
Current Penalty |
1604.0 |
Initial Penalty |
1604.0 |
Final Order |
2017-01-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. a) Storage in corner: On or about August 18, 2016 The scrap storage was stacked to the ceiling and was not stored in an orderly condition. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A02 |
Issuance Date |
2016-12-13 |
Abatement Due Date |
2016-12-21 |
Current Penalty |
2672.0 |
Initial Penalty |
2672.0 |
Final Order |
2017-01-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: a) Fastening Bench: On or about August 18, 2016 The portable grinder was used to cut metal without using the guard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 B07 I |
Issuance Date |
2016-12-13 |
Abatement Due Date |
2016-12-21 |
Current Penalty |
2672.0 |
Initial Penalty |
2672.0 |
Final Order |
2017-01-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment. a) Fastening Bench: On or about August 18, 2016 The welder used to fasten insulation to HVAC was missing the bushing and exposed wiring was evident. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
2016-12-13 |
Abatement Due Date |
2016-12-21 |
Current Penalty |
2672.0 |
Initial Penalty |
2672.0 |
Final Order |
2017-01-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) Near Fastening Bench: On or about August 18, 2016 The disconnect box was not covered when employees used the switch. |
|
|
341710531
|
0215000
|
2016-08-18
|
835 REMSEN AVE, BROOKLYN, NY, 11236
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-08-18
|
Case Closed |
2023-01-11
|
Related Activity
Type |
Complaint |
Activity Nr |
1125948 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1170901 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100132 H01 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-08 |
Current Penalty |
1604.0 |
Initial Penalty |
1604.0 |
Final Order |
2016-12-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(h)(1): Except as provided by paragraphs (h)(2) through (h)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, was not provided by the employer at no cost to employees. a) On or about 8/18/16 at American Metal Fabricators Inc. employees were exposed to chemicals such as but not limited to hexane and toluene, and were not provided with a personal protective equipment at no cost. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-23 |
Current Penalty |
1604.0 |
Initial Penalty |
1604.0 |
Final Order |
2016-12-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about 8/18/16 at American Metal Fabricators Inc. employees were exposed to chemicals such as but not limited to hexane and toluene, and were not provided with a Hazard Communication Program. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-12-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s) (a) On or about 8/19/16 at American Metal Fabricators Inc., employees performing metal fabricating operations were exposed to hazardous chemicals such as but not limited to hexane and toluene without being provided safety data sheets by the employer. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-12-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about 8/19/16 at American Metal Fabricators Inc., employees performing metal fabricating operations were exposed to hazardous chemicals such as but not limited to hexane and toluene without information and training from the employer. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
|
|