343873196
|
0213600
|
2019-03-25
|
13595 BROADWAY, ALDEN, NY, 14004
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-03-25
|
Case Closed |
2019-09-30
|
Related Activity
Type |
Referral |
Activity Nr |
1424450 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2019-05-09 |
Abatement Due Date |
2019-06-10 |
Current Penalty |
3500.0 |
Initial Penalty |
5304.0 |
Contest Date |
2019-05-27 |
Final Order |
2019-09-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) On or about 02/06/19 in the yard truck delivery area; employees were exposed to an unprotected fall from a height of between 53" - 60" from tractor trailer truck beds while they were engaged in the unloading of wooden crates containing glass panels. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100178 A05 |
Issuance Date |
2019-05-09 |
Abatement Due Date |
2019-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
5304.0 |
Contest Date |
2019-05-27 |
Final Order |
2019-09-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) On or about 02/06/19 in and around the yard area and truck unloading; employees were exposed to being struck by wooden crates of glass weighing between 500 - 1,000 pounds when powered industrial trucks (PIT) used boom extensions, such as but not limited to the Caldwell brand fork lift boom (model PB 60 - serial 94217), to lift these wooden crates off of the bed of tractor trailers and name plate on the Toyota PIT ( serial number 10484) did not have the information related to use of the lift boom according to the manufacturer's instructions or approval. ABATMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040029 B03 |
Issuance Date |
2019-05-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2019-05-27 |
Final Order |
2019-09-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.29(b)(3): Each recordable injury or illness on the OSHA 300 Log and 301 Incident Report was not recorded within seven (7) calendar days of receiving information that a recordable injury or illness has occurred. a) On or about 03/25/19 at the administrative offices; employer's 2019 OSHA 300 log did not include an entry for the 02/06/19 lost time injury. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
342920071
|
0213600
|
2018-02-01
|
13595 BROADWAY STREET, ALDEN, NY, 14004
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-02-01
|
Case Closed |
2018-07-02
|
Related Activity
Type |
Referral |
Activity Nr |
1305658 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 O01 |
Issuance Date |
2018-02-05 |
Current Penalty |
2000.0 |
Initial Penalty |
5174.0 |
Contest Date |
2018-02-09 |
Final Order |
2018-05-31 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(o)(1): The employer did not ensure that only stable or safely arranged loads were handled: a) On or about 01/31/2018 in the highway/shipping department; where several glass panels were knocked off a rack while a fork truck was engaging the rack with the forks of the fork truck. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
342301140
|
0213600
|
2017-05-04
|
13595 BROADWAY STREET, ALDEN, NY, 14004
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-05-04
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2017-05-04
|
Related Activity
Type |
Inspection |
Activity Nr |
1195519 |
Safety |
Yes |
|
|
341955193
|
0213600
|
2016-12-06
|
13595 BROADWAY STREET, ALDEN, NY, 14004
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-12-08
|
Emphasis |
N: DUSTEXPL, P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2017-05-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I C |
Issuance Date |
2017-01-10 |
Abatement Due Date |
2017-02-02 |
Current Penalty |
4000.0 |
Initial Penalty |
7572.0 |
Contest Date |
2017-01-25 |
Final Order |
2017-04-20 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection (at least annually)did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 12/06/16 throughout the production area; where employees perform servicing and/or maintenance activities such as, but not limited to: changing dies on a mechanical power press, changing saw blades on "pop-up" saws and wood working equipment. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100217 E01 I |
Issuance Date |
2017-01-10 |
Abatement Due Date |
2017-02-02 |
Current Penalty |
4000.0 |
Initial Penalty |
7572.0 |
Contest Date |
2017-01-25 |
Final Order |
2017-04-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: a) On or about 12/06/2016 in the production area; where the Niagara M22, 22 Ton part revolution mechanical power press (serial # 44818) was used to punch holes in aluminum stock. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2017-01-10 |
Abatement Due Date |
2017-02-02 |
Current Penalty |
2000.0 |
Initial Penalty |
6057.0 |
Contest Date |
2017-01-25 |
Final Order |
2017-04-20 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 12/08/2016 in the production area; where compressed air used for cleaning chips was used with non-self-regulating nozzles and/or non-regulated extension tubes at line pressure (80-90 psi). ABATEMENT CERTIFICATION REQIUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100184 D |
Issuance Date |
2017-01-10 |
Abatement Due Date |
2017-02-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2017-01-25 |
Final Order |
2017-04-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer: a) On or about 12/06/2016 in the shipping department; where wire rope slings were used for loading crated windows onto trucks. Slings were not inspected daily. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100217 E01 I C |
Issuance Date |
2017-01-10 |
Abatement Due Date |
2017-02-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2017-01-25 |
Final Order |
2017-04-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(e)(1)(i)(C): The employer did not maintain a certification record of each inspection, and of each maintenance and repair task performed, (under the general component of the inspection program that includes the date of the inspection, maintenance, or repair work, the signature of the person who performed the inspection, maintenance, or repair work, and the serial number, or other identifier, of the power press inspected, maintained, and repaired): a) On or about 12/06/2016 in the production area; where the Niagara M22, 22 Ton part revolution mechanical power press (serial # 44818) was used to punch holes in aluminum stock; documented records of inspections and maintenance were not maintained. ABATEMENT CERTIFICATION REQUIRED |
|
|