Search icon

GAMMA NORTH CORPORATION

Company Details

Name: GAMMA NORTH CORPORATION
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 30 Aug 2012 (13 years ago)
Entity Number: 4290229
ZIP code: 14004
County: Erie
Place of Formation: New York
Address: 13595 BROADWAY, ALDEN, NY, United States, 14004

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 13595 BROADWAY, ALDEN, NY, United States, 14004

Filings

Filing Number Date Filed Type Effective Date
120830000795 2012-08-30 CERTIFICATE OF INCORPORATION 2012-08-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343873196 0213600 2019-03-25 13595 BROADWAY, ALDEN, NY, 14004
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2019-03-25
Case Closed 2019-09-30

Related Activity

Type Referral
Activity Nr 1424450
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100028 B01 I
Issuance Date 2019-05-09
Abatement Due Date 2019-06-10
Current Penalty 3500.0
Initial Penalty 5304.0
Contest Date 2019-05-27
Final Order 2019-09-19
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) On or about 02/06/19 in the yard truck delivery area; employees were exposed to an unprotected fall from a height of between 53" - 60" from tractor trailer truck beds while they were engaged in the unloading of wooden crates containing glass panels. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Other
Standard Cited 19100178 A05
Issuance Date 2019-05-09
Abatement Due Date 2019-06-10
Current Penalty 0.0
Initial Penalty 5304.0
Contest Date 2019-05-27
Final Order 2019-09-19
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) On or about 02/06/19 in and around the yard area and truck unloading; employees were exposed to being struck by wooden crates of glass weighing between 500 - 1,000 pounds when powered industrial trucks (PIT) used boom extensions, such as but not limited to the Caldwell brand fork lift boom (model PB 60 - serial 94217), to lift these wooden crates off of the bed of tractor trailers and name plate on the Toyota PIT ( serial number 10484) did not have the information related to use of the lift boom according to the manufacturer's instructions or approval. ABATMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19040029 B03
Issuance Date 2019-05-09
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-05-27
Final Order 2019-09-19
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.29(b)(3): Each recordable injury or illness on the OSHA 300 Log and 301 Incident Report was not recorded within seven (7) calendar days of receiving information that a recordable injury or illness has occurred. a) On or about 03/25/19 at the administrative offices; employer's 2019 OSHA 300 log did not include an entry for the 02/06/19 lost time injury. NO ABATEMENT CERTIFICATION REQUIRED
342920071 0213600 2018-02-01 13595 BROADWAY STREET, ALDEN, NY, 14004
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-02-01
Case Closed 2018-07-02

Related Activity

Type Referral
Activity Nr 1305658
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100178 O01
Issuance Date 2018-02-05
Current Penalty 2000.0
Initial Penalty 5174.0
Contest Date 2018-02-09
Final Order 2018-05-31
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(o)(1): The employer did not ensure that only stable or safely arranged loads were handled: a) On or about 01/31/2018 in the highway/shipping department; where several glass panels were knocked off a rack while a fork truck was engaging the rack with the forks of the fork truck. NO ABATEMENT CERTIFICATION REQUIRED
342301140 0213600 2017-05-04 13595 BROADWAY STREET, ALDEN, NY, 14004
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2017-05-04
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2017-05-04

Related Activity

Type Inspection
Activity Nr 1195519
Safety Yes
341955193 0213600 2016-12-06 13595 BROADWAY STREET, ALDEN, NY, 14004
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-12-08
Emphasis N: DUSTEXPL, P: AMPUTATE, N: AMPUTATE
Case Closed 2017-05-05

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C06 I C
Issuance Date 2017-01-10
Abatement Due Date 2017-02-02
Current Penalty 4000.0
Initial Penalty 7572.0
Contest Date 2017-01-25
Final Order 2017-04-20
Nr Instances 1
Nr Exposed 15
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection (at least annually)did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 12/06/16 throughout the production area; where employees perform servicing and/or maintenance activities such as, but not limited to: changing dies on a mechanical power press, changing saw blades on "pop-up" saws and wood working equipment. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19100217 E01 I
Issuance Date 2017-01-10
Abatement Due Date 2017-02-02
Current Penalty 4000.0
Initial Penalty 7572.0
Contest Date 2017-01-25
Final Order 2017-04-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: a) On or about 12/06/2016 in the production area; where the Niagara M22, 22 Ton part revolution mechanical power press (serial # 44818) was used to punch holes in aluminum stock. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19100242 B
Issuance Date 2017-01-10
Abatement Due Date 2017-02-02
Current Penalty 2000.0
Initial Penalty 6057.0
Contest Date 2017-01-25
Final Order 2017-04-20
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 12/08/2016 in the production area; where compressed air used for cleaning chips was used with non-self-regulating nozzles and/or non-regulated extension tubes at line pressure (80-90 psi). ABATEMENT CERTIFICATION REQIUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19100184 D
Issuance Date 2017-01-10
Abatement Due Date 2017-02-02
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2017-01-25
Final Order 2017-04-20
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer: a) On or about 12/06/2016 in the shipping department; where wire rope slings were used for loading crated windows onto trucks. Slings were not inspected daily. ABATEMENT CERTIFICATION REQUIRED
Citation ID 02002
Citaton Type Other
Standard Cited 19100217 E01 I C
Issuance Date 2017-01-10
Abatement Due Date 2017-02-02
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2017-01-25
Final Order 2017-04-20
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(e)(1)(i)(C): The employer did not maintain a certification record of each inspection, and of each maintenance and repair task performed, (under the general component of the inspection program that includes the date of the inspection, maintenance, or repair work, the signature of the person who performed the inspection, maintenance, or repair work, and the serial number, or other identifier, of the power press inspected, maintained, and repaired): a) On or about 12/06/2016 in the production area; where the Niagara M22, 22 Ton part revolution mechanical power press (serial # 44818) was used to punch holes in aluminum stock; documented records of inspections and maintenance were not maintained. ABATEMENT CERTIFICATION REQUIRED

Date of last update: 26 Mar 2025

Sources: New York Secretary of State