340679505
|
0213600
|
2015-06-03
|
HOME SITE #81 DARIEN COURT, LANCASTER, NY, 14086
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-03
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-04-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2015-07-30 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2015-08-21 |
Final Order |
2015-12-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) On or about 6/3/15 at a residential new build located on Darien Court, Lancaster, New York; employees roofing a new house were working from the roof and a ladder jack scaffold. The slack in the rope the employee was attached to hung down past the eaves and scaffold platform allowing potential free fall distances greater than 6 feet. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260502 D17 |
Issuance Date |
2015-07-30 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2015-08-21 |
Final Order |
2015-12-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: a) On or about 6/3/15 at a residential new build located on Darien Court, Lancaster, New York; an employee roofing a new house was wearing a body harness that was not over his shoulders and upper body. The attachment point of the harness was at or near the employee's hips. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2015-07-30 |
Current Penalty |
1500.0 |
Initial Penalty |
10000.0 |
Contest Date |
2015-08-21 |
Final Order |
2015-12-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 6/3/15 at a residential new build located on Darien Court, Lancaster, New York; employees roofing a new house were working from the roof that had a pitch of 6 in 12 and an eave height of approximately 18 feet. Employees were not wearing or utilizing fall protection. NO ABATEMENT CERTIFICATION REQUIRED The employer, Irish Pride Services, was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 977910, citation number 2, item number 1 and was affirmed as a final order on 6/17/14, with respect to a workplace located at 42 Newberry Lane, Lancaster, New York. The employer, Irish Pride Services, was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 543545, citation number 1, item number 1 and was affirmed as a final order on 8/20/12, with respect to a workplace located at 10 Wetherby Way, Lancaster, New York. |
|
|
339779100
|
0213600
|
2014-05-22
|
42 NEWBERRY LANE, LANCASTER, NY, 14086
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-05-22
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-05-31
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2014-06-10 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-06-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 5/22/14 at a residential new build site located at 42 Newberry Lane, Lancaster, New York; employees were using a ladder jack scaffold while installing shingles on the roof. There was no personal fall arrest system in use. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-06-10 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-06-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about 5/22/14 at a residential new build site located at 42 Newberry Lane, Lancaster, New York; employees were using extension ladders to access the ladder jack scaffold and the roof while installing shingles. The ladders only extended 1 foot above the scaffold platform. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B11 |
Issuance Date |
2014-06-10 |
Current Penalty |
2000.0 |
Initial Penalty |
4000.0 |
Final Order |
2014-06-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 5/22/14 at a residential new build site located at 42 Newberry Lane, Lancaster, New York; employees were installing shingles on a new roof with a 7 in 12 pitch and 18 foot eave height. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED Irish Pride Services was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(11), which was contained in OSHA inspection number 543545, citation number 1, item number 1 and was affirmed as a final order on 8/20/12, with respect to a workplace located at 10 Wetherby Way, Lancaster, New York. |
|
|
335435459
|
0213600
|
2012-07-25
|
10 WETHERBY WAY, LANCASTER, NY, 14086
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-07-25
|
Emphasis |
L: FALL
|
Case Closed |
2012-11-16
|
Related Activity
Type |
Inspection |
Activity Nr |
543639 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2012-08-02 |
Current Penalty |
400.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-08-20 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 7/25/12 at a residential new build located at 10 Wetherby Way, Lancaster, New York; employees installing underlayment and asphalt shingles on a roof with an 8 in 12 pitch and an eave height of approximately 9 feet were not protected from falling. NO ABATEMENT CERTIFICATION REQUIRED |
|
|