Search icon

BRIGHTON EXTERIORS LLC

Company Details

Name: BRIGHTON EXTERIORS LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 03 Oct 2012 (13 years ago)
Entity Number: 4303490
ZIP code: 10301
County: Richmond
Place of Formation: New York
Address: 220 VAN BUREN STREET, STATEN ISLAND, NY, United States, 10301

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 220 VAN BUREN STREET, STATEN ISLAND, NY, United States, 10301

Filings

Filing Number Date Filed Type Effective Date
121003000125 2012-10-03 ARTICLES OF ORGANIZATION 2012-10-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340903319 0213400 2015-09-09 1111 VICTORY BLVD., STATEN ISLAND, NY, 10301
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-09-09
Emphasis L: FALL, P: FALL
Case Closed 2019-12-03

Related Activity

Type Complaint
Activity Nr 1025172
Safety Yes
Type Referral
Activity Nr 1017659
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2015-12-30
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2016-02-03
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: a) 1111 Victory Blvd, Staten Island, NY 10301: Employees were allowed to perform stucco operations from a fabricated frame scaffold approximately 13'8" to the ground below that was not fully planked from the front upright to the rear upright. Condition observed on or about October 1, 2015.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2015-12-30
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2016-02-03
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, post, frames, and uprights were not erected on base plates and mud sills, or other adequate firm foundation: a) 1111 Victory Blvd., Staten Island, NY 10301. Employee was exposed to fall hazards in the pump jack scaffold he was erecting was not erected on base plates and mud sills or other adequate firm foundations which affect the structural integrity of the scaffold. Condition occurred on or about 09/03/15.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2015-12-30
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2016-02-03
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffold was erected, used, dismantled, altered, or moved such that the components or any conductive material handled on them might come closer to exposed and energized power lines than three (3) feet: a) 1111 Victory Blvd., Staten Island, NY 10301. Employee was exposed to electrical hazards in that the scaffold he was erecting was in close proximity to energized power lines. Condition occurred on or about 09/03/15.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2015-12-30
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2016-02-03
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled or altered under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed by experienced and trained employees selected for such work by the competent person: a) 1111Victory Blvd., Staten Island, NY 10301. The employee was exposed to fall hazards and electrocution hazards during the erection of Alum-A-Pole pump jack scaffold when the owner, i.e. Competent Person did not or could not recognize the hazards in that: Instance #1  The employer allowed his employee to work on and from the Alum-A-Scaff platform in excess of 11 feet above the ground with no fall protection exposing him to fall hazards. Instance #2  The employer allowed his employee to erect the Alum-A-Pole scaffold within three feet of energized power lines exposing them both to electrocution hazards. Incident occurred on or about 09/03/15.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2015-12-30
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2016-02-03
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a)1111 Victory Blvd., Staten Island, NY 10301: Employees were allowed to perform stucco operations approximately 13'8" from the ground below on a fabricated frame scaffold without fall protection. Condition occurred on October 1, 2015.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State