OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339774473 0216000 2014-05-14 33 ASHBURTON AVE., YONKERS, NY, 10701
Inspection Type Unprog Rel
Scope Complete
Safety/Health Health
Close Conference 2014-05-27
Case Closed 2014-12-22

Related Activity

Type Inspection
Activity Nr 977077
Health Yes
Type Inspection
Activity Nr 987386
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260025 A
Issuance Date 2014-11-07
Abatement Due Date 2014-11-17
Current Penalty 840.0
Initial Penalty 1200.0
Final Order 2014-12-09
Nr Instances 1
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: Location: 33 Ashburton Ave., Yonkers, NY a) Debris such as but not limited to garbage, wooden pallets and other construction debris were not cleared from work areas throughout the worksite; on or about 5/14/14. b) Debris such as but not limited to cardboard boxes, garbage and other construction debris were not cleared from work area throughout the worksite; on or about 7/24/14.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2014-11-07
Abatement Due Date 2015-01-15
Current Penalty 840.0
Initial Penalty 1200.0
Final Order 2014-12-09
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103) Location: 33 Ashburton Ave., Yonkers, NY a) Employees are required to wear respirators such as N95 and 3M half-face negative pressure respirators when chipping and cleaning concrete. The employer had not implemented a written respiratory protection program; on or about 5/19/14.
339777146 0216000 2014-05-14 33 ASHBURTON AVE., YONKERS, NY, 10701
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2014-05-27
Emphasis L: FALL
Case Closed 2015-01-12

Related Activity

Type Inspection
Activity Nr 977084
Safety Yes
Type Inspection
Activity Nr 977464
Safety Yes
Type Inspection
Activity Nr 983347
Safety Yes
Type Inspection
Activity Nr 987219
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2014-11-07
Abatement Due Date 2014-12-05
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-12-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about: 05/14/2014 Location: 33 Ashburton Ave. a) Employees worked in unsafe environments and were not trained to recognize and avoid unsafe conditions.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 B01 II
Issuance Date 2014-11-07
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-12-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(ii): A 120 volt single phase 15 or 20 AMP outlet was not protected by a GFCI or an assured equipment grounding conductor program: On or about: 5/14/2014 Location: Family building, 9th Floor stairwell a) Employees used a Milwaukee hammer drill via an extension cord that were not protected by ground-fault circuit interrupters or an assured equipment grounding conductor program.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2014-11-07
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-12-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: On or about: 7/1/2014 Location: Family building, 9th floor a) Employees used a Milwaukee Hammer Drill which was missing a grounding pin.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-11-07
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2014-12-09
Nr Instances 5
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about: 5/14/2014 Location (a-d): Senior building, 5th floor. (e): Family building, 6th floor a) Employees worked/walked by the edge of the 5th floor and were not protected from falling 5 stories to the ground below. b) Employees worked/walked by the edge of the elevator shaft and were not protected from falling 5 stories to the first floor of the senior building. c) Employees worked/walked by the back side of the stairwell and were not protected from falling 6 feet to the stairway below. d) Employees were sweeping up debris near the edge of the 4th floor and were not protected from falling 4 stories to the ground below. e) Employees worked/walked by the edge of the 6th floor and were not protected from falling 6 stories to the ground below.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2014-11-07
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2014-12-09
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, were not guarded to eliminate the hazard of impalement: On or about: 5/14/14 Location: Senior building, 5th floor. a) Employees worked/walked around unprotected protruding rebar.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2014-11-07
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-12-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge: On or about: 5/14/2014 Location: Senior building, 5th floor. a) Employees used the stairwell which was not equipped with a stairrail system along each unprotected side or edge.
Citation ID 02001
Citaton Type Other
Standard Cited 19260502 B09
Issuance Date 2014-11-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-12-09
Nr Instances 4
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(9): The employer failed to ensure that wire rope used as a top rail was flagged at 6-foot intervals with high-visibility material: On or about: 5/14/2014 Location: Senior building a) The wire rope used as the top rail on the 4th floor was not flagged at 6 foot intervals. b) The wire rope used as the top rail on the 5th floor was not flagged at 6 foot intervals. On or about: 5/14/2014 Location: Family building, 6th floor. c) The wire rope used as the top rail on the 5th floor was not flagged at 6 foot intervals. d) The wire rope used as the top rail on the 6th floor was not flagged at 6 foot intervals.

Date of last update: 26 Mar 2025