Filing Number Date Filed Type Effective Date
DP-2227285 2016-10-26 DISSOLUTION BY PROCLAMATION 2016-10-26
121213000008 2012-12-13 CERTIFICATE OF INCORPORATION 2012-12-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339364119 0213600 2013-08-29 151 SUNSET CENTER LANE, CLARKSON, NY, 14430
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2013-08-29
Emphasis L: FALL, P: FALL
Case Closed 2018-11-01

Related Activity

Type Inspection
Activity Nr 936409
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-09-19
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-10-16
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about 08/29/13, in the Housing Development under construction (Building 1C), located at 151 Sunset Center Lane in Clarkson, New York, employees were installing roof sheathing 16 feet above ground level without the use of fall protection. The employer could not demonstrate that the use of conventional fall protection methods were infeasible or created a greater hazard. NO ABATEMENT CERTIFICATION REQURIED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260502 A02
Issuance Date 2013-09-19
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2013-10-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(a)(2): The employer did not provide and install all fall protection systems required by this subpart for employee(s) and did not comply with all other pertinent requirements of this subpart before employee(s) began the work that necessitates the fall protection. (a) On or about 08/29/13, in the Housing Development (building 1C), under construction, located at 151 Sunset Center Lane in Clarkson, New York, employees were not provided a guardrail system with a top rail measuring between 39 to 45 inches in height from the floor level. NO ABATEMENT CERTIIFICCATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-09-19
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2013-10-16
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) On or about 08/29/13, in the Housing Development, (Building 1C) under construction, located at 151 Sunset Center Lane in Clarkson, New York, an A-Frame ladder which did not extend at least 3 feet above the landing surface, was used to gain access to the second floor. NO ABATEMENT CERTIFICATION REQUIRED

Date of last update: 26 Mar 2025