Search icon

TRISTATE STEEL FIRE PROOFING INC.

Company Details

Name: TRISTATE STEEL FIRE PROOFING INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 24 Dec 2012 (12 years ago)
Entity Number: 4336937
ZIP code: 11205
County: Kings
Place of Formation: New York
Address: 169 CLASSON AVE, BROOKLYN, NY, United States, 11205

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
JOSEPH JACOB Chief Executive Officer 169 CLASSON AVE, BROOKLYN, NY, United States, 11205

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 169 CLASSON AVE, BROOKLYN, NY, United States, 11205

History

Start date End date Type Value
2021-09-01 2023-12-19 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2012-12-24 2021-09-01 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2012-12-24 2016-09-07 Address 881 BEDFORD AVENUE 2ND FLOOR, BROOKLYN, NY, 11205, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
201207062337 2020-12-07 BIENNIAL STATEMENT 2020-12-01
160907000393 2016-09-07 CERTIFICATE OF CHANGE 2016-09-07
121224000169 2012-12-24 CERTIFICATE OF INCORPORATION 2012-12-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345946982 0215000 2022-05-10 350 HENRY ST., BROOKLYN, NY, 11201
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2022-05-10
Case Closed 2022-08-11

Related Activity

Type Inspection
Activity Nr 1331272
Health Yes
343312724 0215000 2018-07-18 350 HENRY ST., BROOKLYN, NY, 11201
Inspection Type Unprog Rel
Scope Partial
Safety/Health Health
Close Conference 2018-07-18

Related Activity

Type Inspection
Activity Nr 1331182
Safety Yes
Type Inspection
Activity Nr 1331194
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100134 C02 II
Issuance Date 2018-12-21
Abatement Due Date 2019-02-11
Current Penalty 2000.0
Initial Penalty 2217.0
Contest Date 2019-01-18
Final Order 2019-09-30
Nr Instances 4
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (Construction Reference 1926.103) (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were observed wearing 3M, Honeywell, and North elastomeric half-face tight-fitting respirators while spraying CAFCO Blaze-Shield II fire resistive material. The employer did not establish and implement the applicable elements of the respiratory protection program. The condition was noted on or about July 7, 2018. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19
Citation ID 01001B
Citaton Type Other
Standard Cited 19100134 D01 III
Issuance Date 2018-12-21
Abatement Due Date 2019-02-11
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-01-18
Final Order 2019-09-30
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (Construction Reference 1926.103) In the alternative 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were exposed to chemical hazards while spraying CAFCO Blaze-Shield II fire resistive material which contains Portland Cement, Quartz (SiO2) throughout the building. The employer did not identify and evaluate the respiratory hazard. The condition was noted on or about July 7, 2018. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01001C
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2018-12-21
Abatement Due Date 2019-02-11
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-01-18
Final Order 2019-09-30
Nr Instances 4
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103) (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were observed wearing 3M, Honeywell, and North elastomeric half-face tight-fitting respirators while spraying CAFCO Blaze-Shield II fire resistive material. The employer did not provide medical evaluation . The condition was noted on or about July 7, 2018. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19
Citation ID 01001D
Citaton Type Other
Standard Cited 19100134 H03 II A
Issuance Date 2018-12-21
Abatement Due Date 2019-02-11
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-01-18
Final Order 2019-09-30
Nr Instances 4
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(h)(3)(ii)(A): Respirator inspections did not include a check of respirator function, tightness of connections, and the condition of the various parts including, but not limited to, the facepiece, head straps, valves, connecting tube, and cartridges, canisters or filters: (Construction Reference 1926.103) (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were observed wearing 3M, Honeywell, and North elastomeric half-face tight-fitting respirators while spraying CAFCO Blaze-Shield II fire resistive material. The employer did not develop and implement a maintenance and care schedule of respirators. The condition was noted on or about July 7, 2018. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19
Citation ID 01001E
Citaton Type Other
Standard Cited 19100134 K01
Issuance Date 2018-12-21
Abatement Due Date 2019-02-11
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-01-18
Final Order 2019-09-30
Nr Instances 4
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(1): 29 CFR 1910.134(k)(1): The employer did not provide effective training that covered the required elements in 1910.134(k)(1)(i) through 1910.134(k)(1)(vii):(Construction Reference 1926.103) (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were observed wearing 3M, Honeywell, and North elastomeric half-face tight-fitting respirators while spraying CAFCO Blaze-Shield II fire resistive material. The employer did not develop and implement a training and information plan. The condition was noted on or about July 7, 2018. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19

Date of last update: 26 Mar 2025

Sources: New York Secretary of State