Search icon

THRESHOLD BUILDERS LLC

Company Details

Name: THRESHOLD BUILDERS LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Inactive
Date of registration: 27 Dec 2012 (12 years ago)
Date of dissolution: 22 Jul 2024
Entity Number: 4338012
ZIP code: 12401
County: Ulster
Place of Formation: New York
Address: 56 VAN DEUSEN, KINGSTON, NY, United States, 12401

DOS Process Agent

Name Role Address
THRESHOLD BUILDERS LLC DOS Process Agent 56 VAN DEUSEN, KINGSTON, NY, United States, 12401

History

Start date End date Type Value
2020-04-02 2024-08-14 Address 56 VAN DEUSEN, KINGSTON, NY, 12401, USA (Type of address: Service of Process)
2013-02-05 2015-05-15 Name WEE LLC
2012-12-27 2013-02-05 Name PRIME WORKS LLC
2012-12-27 2020-04-02 Address 8 HARDER ROAD, WOODSTOCK, NY, 12498, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
240814003631 2024-07-22 CERTIFICATE OF DISSOLUTION-CANCELLATION 2024-07-22
200402060967 2020-04-02 BIENNIAL STATEMENT 2018-12-01
150515000170 2015-05-15 CERTIFICATE OF AMENDMENT 2015-05-15
130205000042 2013-02-05 CERTIFICATE OF AMENDMENT 2013-02-05
121227000128 2012-12-27 ARTICLES OF ORGANIZATION 2012-12-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342413598 0213100 2017-06-21 42 MILL HILL ROAD, WOODSTOCK, NY, 12498
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-06-21
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2018-05-07

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260403 B01 II
Issuance Date 2017-07-18
Abatement Due Date 2017-07-26
Current Penalty 1300.0
Initial Penalty 2173.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1)(ii): Safety of equipment was not determined on the basis of mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: a) Work site - On or about June 21, 2017, the employer was using electric boxes with knockouts for extension cords, which is not what they are listed and labeled for.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2017-07-18
Abatement Due Date 2017-07-26
Current Penalty 1300.0
Initial Penalty 2173.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Work site - On or about June 21, 2017, the employer was using inadequate fittings that did not prevent strain where flexible cords entered electric boxes with knockouts for extension cords.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260405 A02 II F
Issuance Date 2017-07-18
Abatement Due Date 2017-07-26
Current Penalty 1300.0
Initial Penalty 2173.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(F): Temporary lights were suspended by their electric cords when such lights and cords were not designed for suspension: a) Work site - On or about June 21, 2017, the employer had installed temporary lights throughout the building and suspended them by their cords.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2017-07-18
Abatement Due Date 2017-07-26
Current Penalty 1300.0
Initial Penalty 2173.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) East roof - On or about June 21, 2017, employees were working from the lower roof installing the fascia on the upper roof without the use of fall protection.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2017-07-18
Abatement Due Date 2017-07-26
Current Penalty 1300.0
Initial Penalty 2173.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) Northeast corner of deck - Employees were accessing the deck from the incomplete staircase which was approximately 4' from the ground.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2017-07-18
Abatement Due Date 2017-07-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a) East roof - On or about June 21, 2017, employees were working from the lower roof installing the fascia on the upper roof without the use of fall protection. Employees had been trained in fall protection but the employer did not have a written record of such training.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State