Search icon

TRUMP CONSTRUCTION, INC.

Company Details

Name: TRUMP CONSTRUCTION, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 16 Jan 2013 (12 years ago)
Entity Number: 4346744
ZIP code: 10462
County: Bronx
Place of Formation: New York
Address: 2045 HOLLAND AVE, SUITE 1C, BRONX, NY, United States, 10462

Contact Details

Phone +1 347-601-5663

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 2045 HOLLAND AVE, SUITE 1C, BRONX, NY, United States, 10462

Licenses

Number Status Type Date End date
1458179-DCA Inactive Business 2013-02-22 2015-02-28

Filings

Filing Number Date Filed Type Effective Date
130116000452 2013-01-16 CERTIFICATE OF INCORPORATION 2013-01-16

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
1232089 FINGERPRINT INVOICED 2013-02-26 75 Fingerprint Fee
1232086 CNV_TFEE INVOICED 2013-02-22 8.09000015258789 WT and WH - Transaction Fee
1232087 LICENSE INVOICED 2013-02-22 125 Home Improvement Contractor License Fee
1232088 TRUSTFUNDHIC INVOICED 2013-02-22 200 Home Improvement Contractor Trust Fund Enrollment Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334760584 0215800 2012-04-26 5847 ROUTE 11, SANDY CREEK, NY, 13145
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-04-26
Emphasis P: FALL, L: FALL
Case Closed 2013-05-30

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2012-07-13
Abatement Due Date 2012-07-18
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) At the jobsite, on the roof, on or about 4/26/12: Employees were engaged in roofing work on a 6:12 pitch roof at approximately 10 feet and 20 feet ground to eave height, without fall protection of any kind. Abatement certification must be submitted for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2012-07-13
Abatement Due Date 2012-08-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) At the jobsite, on the roof, on or about 4/26/12: Employees were engaged in roofing work on a 6:12 pitch roof at approximately 10 feet and 20 feet ground to eave height, without fall protection of any kind and without being provided training on the hazards associated with falls, or the methods to protect themselves from those hazards. Abatement certification must be submitted for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2012-07-13
Abatement Due Date 2012-07-18
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At the jobsite, on or about 4/26/12: Employees were accessing the roof from the top platform of a scaffold by using a 4 foot step ladder that was leand, unopened, against the eave of the house, and did not extend at least three feet above the upper surface. Abatement certification must be submitted for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2012-07-13
Abatement Due Date 2012-07-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) At the jobsite, on or about 4/26/12: Employees were accessing the roof from the top platform of a scaffold by using a 4 foot step ladder that was leand, unopened, against the eave of the house, and did not extend at least three feet above the upper surface. Abatement certification must be submitted for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2012-07-13
Abatement Due Date 2012-08-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, that enabled each employee to recognize hazards related to ladders and stairways, and that trained each employee in the procedures to be followed to minimize those hazards: a) At the jobsite, on or about 4/26/12: Employees were accessing the roof from the top platform of a scaffold by using a 4 foot step ladder that was leand, unopened, against the eave of the house, did not extend at least three feet above the upper surface, and without having been trained on the use of ladders. Abatement certification must be submitted for this item.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State