341123024
|
0215800
|
2015-12-11
|
11 GREENMAN AVENUE, NEW YORK MILLS, NY, 13417
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-12-11
|
Emphasis |
L: FALL
|
Case Closed |
2017-02-16
|
Related Activity
Type |
Complaint |
Activity Nr |
1045152 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
2016-03-22 |
Abatement Due Date |
2016-03-30 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2016-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: a) South side of building, on or about 12-11-15: One employee was working below three other employees working overhead, without head protection. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-03-22 |
Abatement Due Date |
2016-03-30 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-05-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) South side of roof, on or about 12-11-15: Three employees were working on a 12:12 pitch roof, without fall protection, exposing the employees to a fall hazard of 22 feet 8 inches. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2016-03-22 |
Abatement Due Date |
2016-03-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-05-02 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) 11 Greenman Avenue, entire worksite, on or about 12-11-15: Three employees were performing roof work on a 12:12 pitch roof without the training necessary for the employees to recognize the hazards associated with falls and their work, exposing the employees to a fall hazard of 22 feet 8 inches. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2016-03-22 |
Abatement Due Date |
2016-03-30 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-05-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) South side of roof, on or about 12-11-15: Three employees were accessing a roof via a ladder that was not extended above the landing surface, exposing the employees to a fall hazard of 22 feet 8 inches. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2016-03-22 |
Abatement Due Date |
2016-03-30 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) South side of roof, east end, on or about 12-11-15: One employee was using a step ladder that was not being used as designed or for its intended purpose, exposing the employee to a fall hazard of 22 feet 8 inches. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
|
339919839
|
0215800
|
2014-08-25
|
409 COLUMBIA STREET, UTICA, NY, 13502
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-08-26
|
Emphasis |
L: FALL
|
Case Closed |
2017-01-24
|
Related Activity
Type |
Complaint |
Activity Nr |
905105 |
Safety |
Yes |
|
Type |
Complaint |
Activity Nr |
904987 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260403 B02 |
Issuance Date |
2014-10-07 |
Abatement Due Date |
2014-10-15 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-11-07 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Northwest corner of building, exterior air conditioning unit, on or about 8-25-14: Employees were operating power tools and equipment that were plugged into a relocatable power tap (RPT) that was not being used in accordance with the manufacturers recommendations or as listed and labeled. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 II |
Issuance Date |
2014-10-07 |
Abatement Due Date |
2014-10-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-07 |
Nr Instances |
3 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) Northwest corner of building, exterior air conditioning unit, on or about 8-25-14: Employees were operating power tools and equipment that were powered through a receptacle that was not protected by a ground fault circuit interrupter (GFCI). |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2014-10-07 |
Abatement Due Date |
2014-10-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-07 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Northwest corner of building, exterior air conditioning unit, on or about 8-25-14: Employees were operating power tools and equipment that were plugged into three cords that did not have a continuous path to ground due to a missing a ground pin. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2014-10-07 |
Abatement Due Date |
2014-10-15 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-11-07 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): 29 CFR 1926.501(b)(10): Employee(s) engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8m) or more above lower levels were not protected from falling by a guardrail system, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) West side of roof, on or about 8-25-14: Seven employees were working on a flat roof (2:12 pitch) and were not protected from falls, exposing the employees to a fall hazard of 14 feet 5 inches. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2014-10-07 |
Abatement Due Date |
2014-11-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) West side of roof, on or about 8-25-14: Seven employees were working on a flat roof (2:12 pitch) without the training necessary for those employees to recognize the hazards associated with falls and their work, exposing the employees to a fall hazard of 14 feet 5 inches. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-10-07 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-11-07 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) West side of building, on or about 8-25-14: Seven employees were accessing the roof via an extension ladder that was extended 17 inches above the landing surface, exposing the employees to a fall hazard of 14 feet 5 inches. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2015-06-09 |
Abatement Due Date |
2015-07-06 |
Current Penalty |
400.0 |
Initial Penalty |
400.0 |
Final Order |
2015-07-21 |
Nr Instances |
1 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) At the jobsite, on or about 6/9/2015: The employer did not provide abatement certification for Citation 1, Items 001a, 001b, 001c, 002a, 002b issued on October 7, 2014. An abatement demand letter was sent to the employer on April 21, 2015. Abatement certification is required for this item. |
|
|
339854549
|
0215800
|
2014-07-11
|
600 STATE STREET, UTICA, NY, 13502
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-07-11
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-01-24
|
Related Activity
Type |
Complaint |
Activity Nr |
897526 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2014-09-30 |
Abatement Due Date |
2014-10-08 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-11-21 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. a) At the job site, on or about 7/11/14: Employee were not provided a means of fall protection while performing roofing tasks on a 5 story building. |
|
|