Name: | STANDARD BUILDERS, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 21 Mar 2013 (12 years ago) |
Entity Number: | 4377445 |
ZIP code: | 10467 |
County: | Bronx |
Place of Formation: | New York |
Address: | 2535 MATTHEWS AVE, FL 2, BRONX, NY, United States, 10467 |
Contact Details
Phone +1 917-310-2100
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 2535 MATTHEWS AVE, FL 2, BRONX, NY, United States, 10467 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
2028349-DCA | Inactive | Business | 2015-09-14 | 2023-02-28 |
2002109-DCA | Inactive | Business | 2014-01-02 | 2015-02-28 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
130321000692 | 2013-03-21 | CERTIFICATE OF INCORPORATION | 2013-03-21 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
3276197 | RENEWAL | INVOICED | 2020-12-29 | 100 | Home Improvement Contractor License Renewal Fee |
3276196 | TRUSTFUNDHIC | INVOICED | 2020-12-29 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2933405 | RENEWAL | INVOICED | 2018-11-23 | 100 | Home Improvement Contractor License Renewal Fee |
2933404 | TRUSTFUNDHIC | INVOICED | 2018-11-23 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2835261 | LICENSEDOC10 | CREDITED | 2018-08-31 | 10 | License Document Replacement |
2835265 | LICENSEDOC15 | INVOICED | 2018-08-31 | 15 | License Document Replacement |
2529061 | TRUSTFUNDHIC | INVOICED | 2017-01-09 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2529062 | RENEWAL | INVOICED | 2017-01-09 | 100 | Home Improvement Contractor License Renewal Fee |
2168911 | TRUSTFUNDHIC | INVOICED | 2015-09-14 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2168910 | LICENSE | INVOICED | 2015-09-14 | 75 | Home Improvement Contractor License Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344031661 | 0216000 | 2019-05-23 | 308 241ST STREET, BRONX, NY, 10470 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2019-07-01 |
Current Penalty | 2273.0 |
Initial Penalty | 2273.0 |
Final Order | 2019-09-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A) Exterior on the ground on the right side of the house: An employee was exposed to head injuries while working below masonry activities. The employee was not protected by a hard hat or protective helmet, on or about May 23rd, 2019. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2019-07-01 |
Current Penalty | 3978.0 |
Initial Penalty | 3978.0 |
Final Order | 2019-09-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access. A) Exterior, On the scaffold: An employee was exposed to fall hazards of approximately 22 feet while climbing over a ladder jack scaffold that was not provided with a safe an acceptable means of access, on or about May 23rd, 2019. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2019-07-01 |
Current Penalty | 3978.0 |
Initial Penalty | 3978.0 |
Final Order | 2019-09-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. A) Ladder jack scaffold on the right side of the house: An employee was exposed to fall hazards of approximately 22 feet while working on a ladder jack scaffold that was not protected by a complete guardrail system or another means of fall protection in place, on or about May 23rd, 2019. |
Date of last update: 26 Mar 2025
Sources: New York Secretary of State