OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342116977 0213600 2017-02-17 5542 ROLLING CREEK DRIVE, CLARENCE, NY, 14031
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-02-17
Emphasis L: FALL, P: FALL
Case Closed 2017-06-23
342107737 0213600 2017-02-14 564 NIAGARA STREET, BUFFALO, NY, 14201
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-02-14
Emphasis L: FALL, L: LOCALTARG, P: FALL
Case Closed 2017-05-10

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 A02
Issuance Date 2017-03-14
Current Penalty 1330.0
Initial Penalty 2173.0
Final Order 2017-04-03
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(a)(2): A grounded conductor was attached to a terminal or lead so as to reverse designated polarity: a) On or about 2/14/17 on construction site of a New 4- story Medical Office Bldg. at 564 Niagara St., Buffalo, NY: Employees engaged in installing an EPDM white on black rubber roofing system on a flat rectangular section of the roof in the middle of the building used hand-held electrical equipment such as a Ridgid Model R5011 ½ in. drillmotor with a paddle attachment to mix adhesive, and a Leister hand-held heat welder used in fastening sections of the EPDM rubber roofing system together. A series of two extension cords supplied 120 volt-ac power to those tools. The first cord in the series was plugged into a temporary power receptacle in the basement. That temporary power receptacle was properly wired. The designated polarity of the hot and neutral conductors in the first cord of the series were reversed. The female end of that first cord had been previously replaced, and also had visible damage to the neutral slot. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2017-03-14
Current Penalty 1670.0
Initial Penalty 2716.0
Final Order 2017-04-03
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about 2/14/17 on construction site of a New 4- story Medical Office Bldg. at 564 Niagara St., Buffalo, NY: Employees were engaged in installing an EPDM white on black rubber roofing system on a flat rectangular section of the roof in the middle of the building. This section of the roof was enclosed by high walls on 3 sides. The employer chose to protect workers from falls of approx. 30 ft. from the unprotected north end of this roof by the installation of a guardrail system installed along the north edge. There was a gap left between the wall and the end of the guardrail at the northeast and northwest corners of the roof section where employees could fall off the edge. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260502 B01
Issuance Date 2017-03-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-03
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: Note: When employees are using stilts, the top edge height of the top rail, or equivalent member, shall be increased an amount equal to the height of the stilts. a) On or about 2/14/17 on construction site of a New 4- story Medical Office Bldg. at 564 Niagara St., Buffalo, NY : Employees were engaged in installing an EPDM white on black rubber roofing system on a flat rectangular section of the roof in the middle of the building. This section of the roof was enclosed by high walls on 3 sides. The employer chose to protect workers from falls of approx. 30 ft. from the unprotected north end of this roof by the installation of a guardrail system installed along the north edge. The guardrail system consisted of four vertical posts and three horizontal toprails. The height of the center toprail was approx. 36 inches above the roof. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260502 B02
Issuance Date 2017-03-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-03
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: a) On or about 2/14/17 on construction site of a New 4- story Medical Office Bldg. at 564 Niagara St., Buffalo, NY : Employees were engaged in installing an EPDM white on black rubber roofing system on a flat rectangular section of the roof in the middle of the building. This section of the roof was enclosed by high walls on 3 sides. The employer chose to protect workers from falls of approx. 30 ft. from the unprotected north end of this roof by the installation of a guardrail system installed along the north edge. The guardrail system consisted of four vertical posts and three horizontal toprails. No midrails or equivalent intermediate structural members were installed. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260502 B03
Issuance Date 2017-03-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-03
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: a) On or about 2/14/17 on construction site of a New 4- story Medical Office Bldg. at 564 Niagara St., Buffalo, NY : Employees were engaged in installing an EPDM white on black rubber roofing system on a flat rectangular section of the roof in the middle of the building. This section of the roof was enclosed by high walls on 3 sides. The employer chose to protect workers from falls of approx. 30 ft. from the unprotected north end of this roof by the installation of a guardrail system installed along the north edge. The guardrail system consisted of four vertical posts and three horizontal toprails. The horizontal spans of the toprails were approx. 11 feet , which is greater than the 8 ft . span between vertical posts recommended for wooden guardrails in Appendix B of Subpart M of this standard. NO ABATEMENT CERTIFICATION REQUIRED
339967325 0213600 2014-08-27 6333 MAIN STREET, WILLIAMSVILLE, NY, 14221
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-08-27
Emphasis L: FALL, P: FALL
Case Closed 2014-09-30

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
9498547109 2020-04-15 0296 PPP 6352 Locust Street ext, Lockport, NY, 14094
Loan Status Date 2021-02-06
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 41500
Loan Approval Amount (current) 41500
Undisbursed Amount 0
Franchise Name -
Lender Location ID 46391
Servicing Lender Name Manufacturers and Traders Trust Company
Servicing Lender Address One M & T Plaza, 15th Fl, BUFFALO, NY, 14203
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Lockport, NIAGARA, NY, 14094-1000
Project Congressional District NY-24
Number of Employees 13
NAICS code 238170
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Limited Liability Company(LLC)
Originating Lender ID 46391
Originating Lender Name Manufacturers and Traders Trust Company
Originating Lender Address BUFFALO, NY
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 41784.77
Forgiveness Paid Date 2021-02-16

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
3314099 Intrastate Non-Hazmat 2019-07-23 - - 1 2 Private(Property)
Legal Name SWITALA BERNER CONSTRUCTION LLC
DBA Name -
Physical Address 7187 LINCOLN AVENUE EXT , LOCKPORT, NY, 14094-6217, US
Mailing Address 7187 LINCOLN AVENUE EXT , LOCKPORT, NY, 14094-6217, US
Phone (716) 807-8639
Fax -
E-mail SWITALABERNERCONST@GMAIL.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0