Search icon

TV PARTNERS OF WESTCHESTER CORP.

Company Details

Name: TV PARTNERS OF WESTCHESTER CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 26 Mar 2013 (12 years ago)
Entity Number: 4379050
ZIP code: 10901
County: Rockland
Place of Formation: New York
Address: ONE EXECUTIVE BOULEVARD, SUITE 202, SUFFERN, NY, United States, 10901

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
JULIAN ALAN SCHULMAN, ESQ. DOS Process Agent ONE EXECUTIVE BOULEVARD, SUITE 202, SUFFERN, NY, United States, 10901

Filings

Filing Number Date Filed Type Effective Date
130326000124 2013-03-26 CERTIFICATE OF INCORPORATION 2013-03-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339156739 0216000 2013-06-25 400 MAIN STREET, ARMONK, NY, 10504
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2013-06-28
Emphasis L: FALL, P: FALL
Case Closed 2014-02-28

Related Activity

Type Inspection
Activity Nr 915666
Safety Yes
Type Inspection
Activity Nr 915581
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260502 I03
Issuance Date 2013-12-12
Current Penalty 1500.0
Initial Penalty 2000.0
Final Order 2013-12-12
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: a) Job Site, 1st floor: A floor opening was covered with plywood which was not secured. on or about 6/25/13.
339089872 0216000 2013-05-28 44 BEDFORD RD., ARMONK, NY, 10504
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2013-05-29
Case Closed 2015-01-13

Related Activity

Type Referral
Activity Nr 821014
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2013-11-04
Abatement Due Date 2013-11-15
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2013-12-04
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. location: entire site on or about: 5/14/13 a) Employees were operating Hitatchi nail guns. The employees were not wearing safety shoes. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2013-11-04
Abatement Due Date 2013-11-15
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2013-12-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: location: front of Building A on or about: 5/28/13 a) Employees were engaged in exterior trim work from a pump jack scaffold. The poles beared on planks supported by cinder blocks. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2013-11-04
Abatement Due Date 2013-11-15
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-12-04
Nr Instances 3
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. location: front of Building A on or about: 5/28/13 a) Employees were engaged in exterior trim work from a pump jack scaffold, without fall protection. The employee was exposed to a fall of 21 feet 7 inches. location: side of Building A on or about: 5/28/13 b) Employees were engaged in exterior trim work from a pump jack scaffold, without fall protection. The employee was exposed to a fall of 16 feet 5 inches. location: front of Building A on or about: 5/28/13 c) An employeee was engaged in exterior trim work from a roof bracket scaffold, without fall protection. The employee was exposed to a fall of 24 feet 7 inches. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260452 J02
Issuance Date 2013-11-04
Abatement Due Date 2013-11-15
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-12-04
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. location: front of Building A on or about: 5/28/13 a) Employees were working from a pump jack scaffold without fall protection. The pump jack scaffold was not bracecd at the bottom of the poles. location: side of Building A on or about: 5/28/13 b) Employees were working from a pump jack scaffold without fall protection. The pump jack scaffold was not bracecd at the bottom of the poles. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-11-04
Abatement Due Date 2013-11-15
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-12-04
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. location: roof Building A on or about: 5/28/13 a) An employee was engaged in exterior trim work while on the roof, without fall protection. The employee was exposed to a fall of 24 feet 7 inches. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-11-04
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-12-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access. location: front of Building A on or about: 5/28/13 a) Employee were using a 36 ft. Werner ladder to access a pump jack scaffold. The ladder did not extend 3 ft. above the landing. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01007
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2013-11-04
Abatement Due Date 2013-11-15
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2013-12-04
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for the purposes other than the purpose for which they were designed: location: front of Building A on or about: 5/28/13 a) Employees were using a portable metal extension ladder, while engaged in exterior trim work. The lanyards, connecting the 2 flys of each ladder, were missing. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 02001
Citaton Type Other
Standard Cited 19260404 F06
Issuance Date 2013-11-04
Abatement Due Date 2013-11-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-12-04
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous: location: Building A on or about: 05/28/13 a) Employees were using a DeWalt D28605 cement shear. The shear was plugged into an extension cord that was missing the grounding pin. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 02002
Citaton Type Other
Standard Cited 19260405 J01 II
Issuance Date 2013-11-04
Abatement Due Date 2013-11-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-12-04
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, and receptacles was not securely supported.location: Building A on or about 5/28/13 a) A 4 outlet electrical box was connected to a flexible cord. The box was not secured. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.

Date of last update: 09 Mar 2025

Sources: New York Secretary of State