Search icon

ARROW HOME BUILDERS INC

Company Details

Name: ARROW HOME BUILDERS INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 26 Mar 2013 (12 years ago)
Date of dissolution: 26 May 2016
Entity Number: 4379480
ZIP code: 14072
County: Erie
Place of Formation: New York
Address: 88 RIVERSIDE DRIVE, GRAND ISLAND, NY, United States, 14072

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 88 RIVERSIDE DRIVE, GRAND ISLAND, NY, United States, 14072

Filings

Filing Number Date Filed Type Effective Date
160526000269 2016-05-26 CERTIFICATE OF DISSOLUTION 2016-05-26
130326000698 2013-03-26 CERTIFICATE OF INCORPORATION 2013-03-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340067453 0213600 2014-11-05 1955 GRAND ISLAND BOULEVARD, GRAND ISLAND, NY, 14072
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-11-05
Emphasis L: FALL, P: FALL
Case Closed 2018-11-28

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2014-12-03
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2014-12-31
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On or about 11/05/14, on site of apartment building under construction at 1955 Grand Island Blvd., Grand Island, NY: An extension cord was plugged into a 120 volt-ac receptacle on a Whisperwatt Diesel Powered AC Portable Generator. The extension cord supplied power to a 4-receptacle box, where other extension cords were plugged into. The other extension cords supplied power to various saws being used on the site. No GFCI or assured equipment grounding program was being used. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-12-03
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-12-31
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about 11/05/14, on the roof of apartment building under construction at 1955 Grand Island Blvd., Grand Island, NY: Four employees were exposed to a potential fall of approx. 20 ft. while installing plywood sheathing on the northeast and west sections of the roof. No fall protection system was utilized to protect the employees. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B14
Issuance Date 2014-12-03
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2014-12-31
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, was not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: a) On or about 11/05/14, on the second floor inside the apartment building under construction at 1955 Grand Island Blvd., Grand Island, NY: Employee was exposed to a potential fall of approx. 12 ft. while working next to a window opening at the southwest corner of the building. The bottom edge of each of the approx. twenty window openings was 22 inches above the floor. Each window opening lacked a top rail/cable. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19260404 F06
Issuance Date 2014-12-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-12-31
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 11/05/14, on site of apartment building under construction at 1955 Grand Island Blvd., Grand Island, NY: An extension cord was plugged into a 120 volt-ac receptacle on a Whisperwatt Diesel Powered AC Portable Generator. The extension cord supplied power to a 4-receptacle box, where other extension cords were plugged into. The extension cord that was plugged into the Generator lacked a ground prong on its plug. NO ABATEMENT CERTIFICATION REQUIRED

Date of last update: 26 Mar 2025

Sources: New York Secretary of State