Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-05-24
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2023-01-19
|
Related Activity
Type |
Inspection |
Activity Nr |
1321739 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2018-11-20 |
Current Penalty |
5174.0 |
Initial Penalty |
5174.0 |
Final Order |
2018-12-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which is 6 feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Fall protection cables were taken down at the edge of the 6th floor at the hoist elevator entrance and employees accessed area and were exposed to 60 ft fall hazard. Location: 88 Linden Blvd, Brooklyn NY On or about 5/24/2018 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260502 I03 |
Issuance Date |
2018-11-20 |
Abatement Due Date |
2018-11-28 |
Current Penalty |
3696.0 |
Initial Penalty |
3696.0 |
Final Order |
2018-12-18 |
Nr Instances |
5 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(i)(3): All floor hole covers were not secured when installed so as to prevent accidental displacement by wind, equipment, or employees: a) Floor hole covers were not secured in several locations at the construction site; including but not limited to a hole in the temporary floor over the elevator shaft and at the bottom of the stairwell. Location: 88 Linden Blvd, Brooklyn NY; cellar and upper floors; On or about 5/24/2018 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260502 I04 |
Issuance Date |
2018-11-20 |
Abatement Due Date |
2018-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-18 |
Nr Instances |
5 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(i)(4): All floor hole covers were not color coded or marked with the word HOLE or COVER to provide warning of the hazard: a) Floor hole covers at the construction site were not coded or marked; employees were exposed to floor hole hazard. Location: 88 Linden Blvd, Brooklyn NY On or about 5/24/2018 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19. |
|
|