Search icon

TREND 21 MANAGEMENT INC.

Company Details

Name: TREND 21 MANAGEMENT INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 17 Apr 2013 (12 years ago)
Entity Number: 4389809
ZIP code: 11358
County: Queens
Place of Formation: New York
Address: 167-17 NORTHERN BLVD., FLUSHING, NY, United States, 11358

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
TREND 21 MANAGEMENT INC DOS Process Agent 167-17 NORTHERN BLVD., FLUSHING, NY, United States, 11358

Chief Executive Officer

Name Role Address
VICTOR CHON Chief Executive Officer 167-17 NORTHERN BLVD., FLUSHING, NY, United States, 11358

Permits

Number Date End date Type Address
X012019070B24 2019-03-11 2019-04-06 PAVE STREET-W/ ENGINEERING & INSP FEE EAST 233 STREET, BRONX, FROM STREET BAYCHESTER AVENUE TO STREET EDSON AVENUE
X012019070B23 2019-03-11 2019-04-06 RESET, REPAIR OR REPLACE CURB EAST 233 STREET, BRONX, FROM STREET BAYCHESTER AVENUE TO STREET EDSON AVENUE
X012019070B22 2019-03-11 2019-04-06 PAVE STREET-W/ ENGINEERING & INSP FEE BAYCHESTER AVENUE, BRONX, FROM STREET EAST 233 STREET TO STREET STRANG AVENUE
X012019070B21 2019-03-11 2019-04-06 RESET, REPAIR OR REPLACE CURB BAYCHESTER AVENUE, BRONX, FROM STREET EAST 233 STREET TO STREET STRANG AVENUE
S012019028B38 2019-01-28 2019-02-24 PAVE STREET-W/ ENGINEERING & INSP FEE BAY STREET, STATEN ISLAND, FROM STREET ST MARY'S AVENUE
S012019028B34 2019-01-28 2019-02-22 RESET, REPAIR OR REPLACE CURB BAY STREET, STATEN ISLAND, FROM STREET LUKE M PARLATORE WAY TO STREET CHURCH LANE
S012019028B35 2019-01-28 2019-02-22 RESET, REPAIR OR REPLACE CURB ST MARYS AVENUE, STATEN ISLAND, FROM STREET BAY STREET TO STREET ORMOND PLACE
S012019028B36 2019-01-28 2019-02-22 PAVE STREET-W/ ENGINEERING & INSP FEE BAY STREET, STATEN ISLAND, FROM STREET LUKE M PARLATORE WAY TO STREET CHURCH LANE
S012019028B37 2019-01-28 2019-02-22 PAVE STREET-W/ ENGINEERING & INSP FEE ST MARYS AVENUE, STATEN ISLAND, FROM STREET BAY STREET TO STREET ORMOND PLACE
X012019018A52 2019-01-18 2019-02-16 PAVE STREET-W/ ENGINEERING & INSP FEE TAYLOR AVENUE, BRONX, FROM STREET GLEASON AVENUE TO STREET WESTCHESTER AVENUE

History

Start date End date Type Value
2022-02-10 2023-12-20 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-12-06 2022-02-10 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-09-14 2021-12-06 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2013-04-17 2021-09-14 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2013-04-17 2018-05-31 Address 163-32 NORTHERN BLVD. SUITE 2E, FLUSHING, NY, 11358, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
190416060487 2019-04-16 BIENNIAL STATEMENT 2019-04-01
180531006040 2018-05-31 BIENNIAL STATEMENT 2017-04-01
130417000542 2013-04-17 CERTIFICATE OF INCORPORATION 2013-04-17

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2023-10-07 No data 11 AVENUE, FROM STREET 131 STREET TO STREET 132 STREET No data Street Construction Inspections: Pick-Up Department of Transportation Respondent used cones, sand bags and caution tape to occupy the roadway at side of 11-11 131st Street to do exterior wall work without a DOT permit/authorization . DOB permit Q00873876-I1-GC for work on building was used to identify respondent.
2022-03-19 No data BAYCHESTER AVENUE, FROM STREET EAST 233 STREET TO STREET STRANG AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb in place
2021-12-21 No data BAY STREET, FROM STREET LUKE M PARLATORE WAY TO STREET CHURCH LANE No data Street Construction Inspections: Post-Audit Department of Transportation Curb is ok
2021-09-28 No data EAST 233 STREET, FROM STREET BAYCHESTER AVENUE TO STREET EDSON AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation curb in place
2021-09-15 No data ST MARYS AVENUE, FROM STREET BAY STREET TO STREET ORMOND PLACE No data Street Construction Inspections: Post-Audit Department of Transportation CURB WAS INSTALLED
2021-09-11 No data BAY STREET, FROM STREET LUKE M PARLATORE WAY TO STREET CHURCH LANE No data Street Construction Inspections: Post-Audit Department of Transportation CURB WAS INSTALLED
2021-01-03 No data DEVOE STREET, FROM STREET GRAHAM AVENUE TO STREET HUMBOLDT STREET No data Street Construction Inspections: Post-Audit Department of Transportation Curb reveal installed adjacent to property AKA #324 GRAHAM AVENUE in compliance
2020-11-09 No data ATLANTIC AVENUE, FROM STREET BUFFALO AVENUE TO STREET KANE PLACE No data Street Construction Inspections: Post-Audit Department of Transportation NO VISIBLE WORK DONE.
2020-09-27 No data GRAHAM AVENUE, FROM STREET AINSLIE STREET TO STREET DEVOE STREET No data Street Construction Inspections: Post-Audit Department of Transportation Roadway paved & resurfaced restored in kind in prestigious condition in compliance
2020-09-17 No data ATLANTIC AVENUE, FROM STREET BUFFALO AVENUE TO STREET KANE PLACE No data Street Construction Inspections: Post-Audit Department of Transportation NO WORK DONE PERMIT EXPIRED

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344237227 0215000 2019-08-16 5919 FLATLANDS AVENUE, BROOKLYN, NY, 11234
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2019-08-16
Case Closed 2019-09-24

Related Activity

Type Inspection
Activity Nr 1228083
Safety Yes
342280831 0215000 2017-04-27 1709 ST MARKS AVE, BROOKLYN, NY, 11233
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-04-27
Emphasis L: FALL, N: SVEP, P: FALL
Case Closed 2019-10-31

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260350 A01
Issuance Date 2017-06-21
Current Penalty 1700.0
Initial Penalty 2987.0
Final Order 2018-11-20
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.350(a)(1): Valve protection cap(s) in place were not in place and secured on compressed gas cylinder(s) Location: a) On the northwest side of the building: On or about 04/27/17, valve protection cap were not in place and secured on a compressed gas cylinder.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260350 A09
Issuance Date 2017-06-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-20
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times. Location: a) On the northwest side of the building: On or about 04/27/17, compressed gas cylinders were not secured in upright positions.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260350 A10
Issuance Date 2017-06-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-20
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour. Location: a) On the northwest side of the building: On or about 04/27/17, oxygen cylinders in storage were not separated from fuel-gas cylinder, a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2017-06-21
Current Penalty 1700.0
Initial Penalty 2987.0
Final Order 2018-11-20
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation. Location: a) Supported scaffold on the northwest side of the building: On or about 04/27/17, employees were demolishing a cement block wall on the second tier platform of a 3-tier-high supported scaffold. The supported scaffold legs did not bear on base plates, mud sills or other adequate firm foundation.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2017-06-21
Abatement Due Date 2017-07-03
Current Penalty 2400.0
Initial Penalty 4183.0
Final Order 2018-11-20
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Location: a) Supported scaffold on the northwest side of the building: On or about 04/27/17, the employer did not provide training to an employee who worked on a supported scaffold.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260451 B01
Issuance Date 2017-06-21
Current Penalty 4900.0
Initial Penalty 8366.0
Final Order 2018-11-20
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Location: a) Supported scaffold on the northwest side of the building: On or about 04/27/17, employees were demolishing a cement block wall on the second tier platform of a 3-tier-high supported scaffold that was not fully planked or decked between front upright and the guardrail supports, and were exposed to falling approximately 12 feet to the lower level. Trend 21 Management Inc. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1926.451(b)(1), which was contained in OSHA inspection number 1060878, citation number 1, item number 4 and was affirmed as a final order on 05/20/2016, with respect to a workplace located at 1452 Westchester Avenue, Bronx, N.Y. 10472
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260451 E01
Issuance Date 2017-06-21
Current Penalty 4900.0
Initial Penalty 8366.0
Final Order 2018-11-20
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Location: a) Supported scaffold on the northwest side of the building: On or about 04/27/17, employees climbed the crossbrace as a mean of access to the second tier platform of a 3-tier-high supported scaffold. Trend 21 Management Inc. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1926.451(e)(1), which was contained in OSHA inspection number 1060878, citation number 1, item number 6 and was affirmed as a final order on 05/20/2016, with respect to a workplace located at 1452 Westchester Avenue, Bronx, N.Y. 10472
Citation ID 02003
Citaton Type Repeat
Standard Cited 19260451 G01 VII
Issuance Date 2017-06-21
Current Penalty 4900.0
Initial Penalty 8366.0
Final Order 2018-11-20
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: a) Supported scaffold on the northwest side of the building: On or about 04/27/17, employees were demolishing a cement block wall on the second tier platform of a 3-tier-high supported scaffold, and were exposed to falling approximately 12 feet to the lower level. Trend 21 Management Inc. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1926.451(g)(1), which was contained in OSHA inspection number 1060878, citation number 1, item number 7 and was affirmed as a final order on 05/20/2016, with respect to a workplace located at 1452 Westchester Avenue, Bronx, N.Y. 10472
340608785 0216000 2015-05-05 1452 WESTCHESTER AVE., BRONX, NY, 10472
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2015-05-12
Emphasis L: FALL
Case Closed 2016-09-14

Related Activity

Type Referral
Activity Nr 981372
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2015-06-10
Current Penalty 1200.0
Initial Penalty 2000.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 4
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about 5/5/2015, Westchester Ave. a) The employer did not provide safety and health training as required by the standard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260025 A
Issuance Date 2015-06-10
Current Penalty 960.0
Initial Penalty 1600.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: On or about 5/5/2015, Westchester Ave. a) There were empty buckets, broken pieces of wood and cinderblock obstructing the passageway.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2015-06-10
Current Penalty 960.0
Initial Penalty 1600.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 4
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about 5/5/2015, Westchester Ave. a) The employees were applying stucco to the side of the building and were not wearing eye protection.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2015-06-10
Current Penalty 1600.0
Initial Penalty 2800.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 5/5/2015, Westchester Ave. a) The work platform had three 2x10 planks, exposing the employees to a 12' fall hazard.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2015-06-10
Current Penalty 1200.0
Initial Penalty 2000.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: On or about 5/5/2015, Westchester Ave. a) The tubular welded frame scaffold was missing cross bracing and baseplates and exposed the employees to a fall hazard.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2015-06-10
Current Penalty 1200.0
Initial Penalty 2000.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 4
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: On or about 5/5/2015, Westchester Ave. a) The employees climbed on the frame of the tubular welded scaffold.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2015-06-10
Current Penalty 1680.0
Initial Penalty 2800.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: On or about 5/5/2015, Westchester Ave. a) The employees worked from a tubular welded frame scaffold and were not protected from falling 12' to the ground below.
Citation ID 02001
Citaton Type Other
Standard Cited 19260050 G
Issuance Date 2015-06-10
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.50(g): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about 5/5/2015, Westchester Ave. a) The employees used poly blend and portland cement and were not provided with an eye wash.
Citation ID 02002A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2015-06-10
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 4
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59): On or about 5/5/2015, Westchester Ave. a) The employer did not follow the requirements for the hazard communication program.
Citation ID 02002B
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 2015-06-10
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 4
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical: On or about 5/5/15, Westchester Ave. a) The employees used a polyblend, sand and portland cement for the stucco. They were not provided with the material safety data sheets.
Citation ID 02002C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2015-06-10
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-07-17
Final Order 2016-05-20
Nr Instances 3
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about 5/5/15, Westchester Ave. a) The employees were not provided effective information and tarining as required by the standard.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
6530047207 2020-04-28 0202 PPP 167-17 NORTHERN BLVD, FLUSHING, NY, 11358
Loan Status Date 2021-10-09
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 60100
Loan Approval Amount (current) 60100
Undisbursed Amount 0
Franchise Name -
Lender Location ID 338036
Servicing Lender Name PCB Bank
Servicing Lender Address 3701 Wilshire Blvd, Ste 900, LOS ANGELES, CA, 90010-2871
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address FLUSHING, QUEENS, NY, 11358-0001
Project Congressional District NY-03
Number of Employees 6
NAICS code 236220
Borrower Race Unanswered
Borrower Ethnicity Not Hispanic or Latino
Business Type Corporation
Originating Lender ID 338036
Originating Lender Name PCB Bank
Originating Lender Address LOS ANGELES, CA
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 60857.42
Forgiveness Paid Date 2021-08-05
4353048409 2021-02-06 0202 PPS 16717 Northern Blvd, Flushing, NY, 11358-2638
Loan Status Date 2021-12-17
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 60100
Loan Approval Amount (current) 60100
Undisbursed Amount 0
Franchise Name -
Lender Location ID 444264
Servicing Lender Name NewBank
Servicing Lender Address 146-01, Northern Blvd, Queens, NY, 11354
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Flushing, QUEENS, NY, 11358-2638
Project Congressional District NY-06
Number of Employees 6
NAICS code 236220
Borrower Race Unanswered
Borrower Ethnicity Not Hispanic or Latino
Business Type Corporation
Originating Lender ID 444264
Originating Lender Name NewBank
Originating Lender Address Queens, NY
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 60582.47
Forgiveness Paid Date 2021-12-01

Date of last update: 26 Mar 2025

Sources: New York Secretary of State