Name: | PANELLA & SON CONSTRUCTION, INC |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 23 Apr 2013 (12 years ago) |
Entity Number: | 4392397 |
ZIP code: | 14626 |
County: | Monroe |
Place of Formation: | New York |
Address: | 26 NYMARK DRIVE, ROCHESTER, NY, United States, 14626 |
Shares Details
Shares issued 100
Share Par Value 0.01
Type PAR VALUE
Name | Role | Address |
---|---|---|
REBECCA S. TORCHIA | Agent | 26 NYMARK DRIVE, ROCHESTER, NY, 14626 |
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 26 NYMARK DRIVE, ROCHESTER, NY, United States, 14626 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
130423000228 | 2013-04-23 | CERTIFICATE OF INCORPORATION | 2013-04-23 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347695744 | 0213600 | 2024-08-16 | ETNA TRAIL LOT 207R, BROCKPORT, NY, 14420 | |||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1769741 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2024-09-17 |
Current Penalty | 1498.5 |
Initial Penalty | 1998.0 |
Final Order | 2024-09-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about 08/16/2024, during the new home construction located on Etna Trail, in Brockport, New York, the employer did not enforce the use of fall protection when employees were installing sub floor panels on an elevated surface 12 feet above lower levels. Employees were exposed to fall hazards. NO ABATEMENT CERTIFICATION REQUIRED |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2022-04-26 |
Emphasis | P: FALL, L: FALL |
Case Closed | 2023-04-21 |
Related Activity
Type | Inspection |
Activity Nr | 1591890 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2022-09-22 |
Current Penalty | 3263.25 |
Initial Penalty | 4351.0 |
Final Order | 2022-10-07 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): (a) At the jobsite, Lot 59 Cottages, on or about 4/26/2022: Employees were installing trusses, that were being hoisted by a crane, on a new residential structure. The employees were working at in excess of 9' off the ground without fall protection of any kind. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2018-09-07 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2019-03-14 |
Related Activity
Type | Inspection |
Activity Nr | 1348655 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2018-09-21 |
Current Penalty | 1200.0 |
Initial Penalty | 2136.0 |
Final Order | 2018-10-05 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about 09/07/18, during the installation of roof sheathing and exterior residential framing, employees were exposed to falling 16 feet to ground level, as a result of not wearing or having conventional fall protection. NO ABATEMENT CERTIFICATION REQUIRED |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2131577109 | 2020-04-10 | 0219 | PPP | 26 NYMARK DR, ROCHESTER, NY, 14626-1261 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3832388300 | 2021-01-22 | 0219 | PPS | 26 Nymark Dr, Rochester, NY, 14626-1261 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 26 Mar 2025
Sources: New York Secretary of State