Search icon

ALBO RENOVATIONS INC.

Company Details

Name: ALBO RENOVATIONS INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 30 Apr 2013 (12 years ago)
Date of dissolution: 26 Oct 2016
Entity Number: 4396504
ZIP code: 11566
County: Nassau
Place of Formation: New York
Address: 2768 LINDENMERE DR., MERRICK, NY, United States, 11566

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 2768 LINDENMERE DR., MERRICK, NY, United States, 11566

Filings

Filing Number Date Filed Type Effective Date
DP-2233961 2016-10-26 DISSOLUTION BY PROCLAMATION 2016-10-26
130430000921 2013-04-30 CERTIFICATE OF INCORPORATION 2013-04-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339077091 0215800 2013-05-21 9 MAIN STREET, SIDNEY, NY, 13838
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2013-05-21
Emphasis L: FALL
Case Closed 2017-01-12

Related Activity

Type Inspection
Activity Nr 907726
Safety Yes
Type Complaint
Activity Nr 819799
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2013-08-13
Nr Instances 4
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) First floor, on or about 5-21-13: Two employees were operating power tools that were plugged into multiple electrical boxes/cord assemblies that were not being used as designed or as "listed and labeled".
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260403 I02 I
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures: a) First floor, southeast corner, on or about 5-21-13: Two employees were accessing power through a panel box where breakers were missing and the openings uncovered and/or covered with duct tape.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260404 B01 II
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 4
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) First floor, on or about 5-21-13: Two employees were operating power tools that were plugged into multiple electrical boxes/cord assemblies that were not protected by a ground fault circuit interrupter (GFCI).
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) First floor, on or about 5-21-13: Two employees were operating power tools that were plugged into a power source that did not have a continuous path to ground due to a missing a ground pin.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): 29 CFR 1926.450(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: a) North side of building, west end, on or about 5-21-13: Two employees were working on a scaffold that was not fully planked, exposing the employees to a fall hazard of 29 feet 8 inches.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) North side of building, west end, on or about 5-21-13: Two employees were working on a scaffold platform that was less than 18 inches wide, exposing the employee to a fall hazard of 29 feet 8 inches.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 B05 I
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches, and was not designed and installed so that the cantilevered portion of the platform was able to support employees and/or materials without tipping, or had guardrails which blocked employee access to the cantilevered end: a) North side of building, west end, on or about 5-21-13: Two employees were working on a scaffold plank that was extended 20 inches beyond the support, exposing the employee to a fall hazard of 29 feet 8 inches.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) North side of building, west end, on or about 5-21-13: Two employees were working on the end of a scaffold platform without fall protection, exposing the employee to a fall hazard of 29 feet 8 inches. b) North side of building, on or about 5-21-13: Two employees were working on a scaffold platform without fall protection, exposing the employee to a fall hazard of 10 feet 8 inches.
Citation ID 01002E
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) North side of building, on or about 5-21-13: Two employees were working on a scaffold system that was not inspected by a competent person.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) East side of building, on or about 5-21-13: Three employees were working on a sloped roof and were not protected from falls, exposing the employees to a fall hazard 36 feet 6 inches.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260602 C01 VIII A
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(c)(1)(viii)(A): The safety platform was not firmly secured to the lifting carriage and/or forks. a) East side of building, on or about 5-21-13: Employees were unloading building materials while standing on a wood pallet platform hoisted on an all-terrain lift and was not secured to the lifting carriage and/or forks. b) East side of building, on or about 5-21-13: Employees were unloading building materials while standing on a steel grate platform hoisted on an all-terrain lift and was not secured to the lifting carriage and/or forks.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260602 C01 VIII B
Issuance Date 2013-07-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(c)(1)(viii)(B): Means were not provided whereby personnel on the platform could shut off power to the truck: a) East side of building, on or about 5-21-13: Employees were unloading building materials while standing on a wood pallet platform hoisted on an all-terrain lift that was left unattended, without a person at the controls. b) East side of building, on or about 5-21-13: Employees were unloading building materials while standing on a steel grate platform hoisted on an all-terrain lift that left unattended, without a person at the controls.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260850 A
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.850(a): Prior to permitting employees to start demolition operations, an engineering survey was not made by a competent person of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure, including adjacent structures where employees may be exposed. The employer did not have in writing evidence that such a survey was performed: a) Entire roof, on or about 5-21-13: Three employees were performing masonry demolition work on a structurally compromised roof of a building without an engineering survey by a competent person.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260850 B
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.850(b): The walls or floors were not shored or braced where employee(s) were required to work within a damaged structure to be demolished: a) Entire roof, on or about 5-21-13: Three employees were performing masonry demolition work on a structurally compromised roof of a building without an engineering survey by a competent person.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2013-08-13
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a) North side of building, on or about 5-21-13: Employees were accessing/egressing an upper roof surface from a lower roof surface that had a change in elevation ranging from 42 inches to 48 inches.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: a) Northeast corner of building, on or about 5-21-13: Employees were accessing the roof via an extension ladder that was extended 23 inches above the landing surface, exposing the employees to a fall hazard of 14 feet. b) South side of building, 3rd floor bathroom, on or about 5-21-13: Employees were accessing the roof via a step ladder that was 20 inches above the window sill surface, exposing the employees to a fall hazard of 4 feet 11 inches.
Citation ID 01006C
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2013-07-19
Abatement Due Date 2013-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-13
Nr Instances 2
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were not used for the purpose for which they were designed: a) North side of building, on or about 5-21-13: Employees were using a 6 foot step ladder for building a scaffold, that was folded and leaning against a wall, not being used as designed or for its intended purpose. b) South side of building, 3rd floor bathroom, on or about 5-21-13: Employees were accessing the roof via an 8 foot step ladder that was folded and leaning against a wall, not being used as designed or for its intended purpose.

Date of last update: 26 Mar 2025