342592961
|
0215000
|
2017-08-11
|
54 FULTON STREET, NEW YORK, NY, 10038
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-11
|
Emphasis |
L: LOCALTARG
|
Case Closed |
2017-08-11
|
Related Activity
Type |
Inspection |
Activity Nr |
1259289 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1259303 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1259264 |
Safety |
Yes |
|
|
341612596
|
0215000
|
2016-06-16
|
7 WEST 21ST STREET, NEW YORK CITY, NY, 10004
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-06-16
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2016-09-14
|
Related Activity
Type |
Inspection |
Activity Nr |
1161269 |
Safety |
Yes |
|
|
339599789
|
0215000
|
2014-02-24
|
425 W. 50TH ST, NEW YORK, NY, 10019
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-02-24
|
Emphasis |
L: FALL
|
Case Closed |
2015-02-04
|
Related Activity
Type |
Referral |
Activity Nr |
873472 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2014-04-08 |
Current Penalty |
1750.0 |
Initial Penalty |
3500.0 |
Final Order |
2014-04-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. a) 17th Floor South East Corner: On or about February 21, 2014 A baker scaffold which was owned by another subcontractor was not properly inspected before use. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260454 C03 |
Issuance Date |
2014-04-08 |
Abatement Due Date |
2014-04-17 |
Current Penalty |
1400.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-04-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(c)(3): Where inadequacies in an affected employee's work involving scaffolds indicate that the employee has not retained the requisite proficiency. a) 17th Floor South East Corner: On or about February 21, 2014 Re-training in scaffold examination was inadequate. |
|
|
334621604
|
0215000
|
2012-06-08
|
210 W. 18TH ST, NEW YORK, NY, 10018
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-06-08
|
Emphasis |
L: FALL
|
Case Closed |
2013-07-26
|
Related Activity
Type |
Inspection |
Activity Nr |
462258 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
425092 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
462400 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
462359 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260304 H |
Issuance Date |
2012-07-19 |
Current Penalty |
1750.0 |
Initial Penalty |
3500.0 |
Final Order |
2012-07-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(h): "Hand-fed crosscut table saws."Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws. a) Unit 11C living room: On or about June 8, 2012 Employees were using a DeWalt DW745 table saw with no guard while cutting wood boards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2012-07-19 |
Current Penalty |
1400.0 |
Initial Penalty |
2800.0 |
Final Order |
2012-07-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a) 21st floor North side: On or about 6/8/2012 An employee used a DeWalt Saw which was plugged in by extension cord. The saw cord was missing the ground pin. |
|
|
313004269
|
0216000
|
2010-08-11
|
850 JENNINGS AVENUE, BRONX, NY, 10453
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2010-08-12
|
Emphasis |
S: ELECTRICAL, S: RESIDENTIAL CONSTR, L: LOCALTARG
|
Case Closed |
2010-11-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260025 A |
Issuance Date |
2010-09-22 |
Abatement Due Date |
2010-10-15 |
Current Penalty |
210.0 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260405 A02 IIF |
Issuance Date |
2010-09-22 |
Abatement Due Date |
2010-10-15 |
Current Penalty |
525.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260405 A02 IIE |
Issuance Date |
2010-09-22 |
Abatement Due Date |
2010-09-27 |
Current Penalty |
525.0 |
Initial Penalty |
750.0 |
Nr Instances |
15 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 |
Issuance Date |
2010-09-22 |
Abatement Due Date |
2010-09-27 |
Current Penalty |
525.0 |
Initial Penalty |
600.0 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
02 |
|
|
309642221
|
0215000
|
2006-01-11
|
353 4TH AVE., BROOKLYN, NY, 11215
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2006-01-24
|
Case Closed |
2006-04-28
|
Related Activity
Type |
Referral |
Activity Nr |
202645685 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2006-01-25 |
Abatement Due Date |
2006-01-31 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2006-01-25 |
Abatement Due Date |
2006-01-31 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260251 C05 |
Issuance Date |
2006-01-25 |
Abatement Due Date |
2006-01-31 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
6 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260502 D15 |
Issuance Date |
2006-01-25 |
Abatement Due Date |
2006-01-31 |
Nr Instances |
6 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2006-01-25 |
Abatement Due Date |
2006-02-02 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260302 E01 |
Issuance Date |
2006-01-25 |
Abatement Due Date |
2006-02-02 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
|
309525251
|
0215000
|
2005-12-22
|
353 4TH AVE., BROOKLYN, NY, 11215
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2005-12-22
|
Emphasis |
L: FALL
|
Case Closed |
2006-02-06
|
Related Activity
Type |
Complaint |
Activity Nr |
205613441 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B01 |
Issuance Date |
2006-01-05 |
Abatement Due Date |
2006-01-10 |
Current Penalty |
3200.0 |
Initial Penalty |
4000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
|