Search icon

CL REMODELING CORP.

Company Details

Name: CL REMODELING CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 07 Jun 2013 (12 years ago)
Entity Number: 4414890
ZIP code: 10509
County: Putnam
Place of Formation: New York
Address: 440 MAPLE ROAD, BREWSTER, NY, United States, 10509

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 440 MAPLE ROAD, BREWSTER, NY, United States, 10509

Filings

Filing Number Date Filed Type Effective Date
130607000867 2013-06-07 CERTIFICATE OF INCORPORATION 2013-06-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344160080 0216000 2019-05-29 15 OVERHILL ROAD, BRONXVILLE, NY, 10708
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-05-29
Emphasis L: FALL, P: FALL
Case Closed 2021-08-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-07-22
Current Penalty 1500.0
Initial Penalty 3069.0
Final Order 2019-08-06
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: A) Exterior, On the roof on the right side of the house: An employee was exposed to eye/face injuries while using a pneumatic nail gun and was not protected with any type of eye/face protection, on or about May 29th, 2019.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-07-22
Current Penalty 1800.0
Initial Penalty 3580.0
Final Order 2019-08-06
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b) A) Roof of the structure, In the front of the house: An employee was exposed to fall hazards of approximately 10 feet while engaged in roofing work on the roof of a structure without a means of fall protection in place, on or about May 29th, 2019. B) Roof of the structure, on the Upper roof in the rear of the house: An employee was exposed to fall hazards of approximately 23 feet while engaged in roofing work on the roof of a structure without a means of fall protection in place, on or about May 29th, 2019.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2019-07-22
Current Penalty 1500.0
Initial Penalty 3069.0
Final Order 2019-08-06
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: A) Exterior, In the front of the house: An employee was exposed to fall hazards of approximately 11 feet while using an extension ladder that was not extended at least 3 feet over the landing that they were accessing, on or about May 29th, 2019.
340713544 0216000 2015-06-11 8 HEATHCOTE RD., SCARSDALE, NY, 10583
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2015-06-11
Case Closed 2015-11-18

Related Activity

Type Inspection
Activity Nr 1071293
Safety Yes

Date of last update: 26 Mar 2025

Sources: New York Secretary of State