OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338996242 0214700 2013-04-10 315 LIDO BLVD., LIDO BEACH, NY, 11561
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2013-04-10
Emphasis L: SANDY, L: FALL, P: FALL
Case Closed 2013-11-19

Related Activity

Type Inspection
Activity Nr 899612
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2013-04-25
Abatement Due Date 2013-05-01
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-06-06
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 315 Lido Blvd, Lido Beach NY- Employees were not wearing protective helmets and were exposed to being struck by asphalt shingles and tools while walking and working below overhead roofing work; on or about 04/10/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-04-25
Abatement Due Date 2013-05-01
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-06-06
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) Worksite, 315 Lido Blvd. Lido Beach NY - Employees were removing asphalt shingles on the roof of a residential home. The employees were not protected from falling approximately 20ft to the ground below; on or about 04/10/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B22
Issuance Date 2013-04-25
Abatement Due Date 2013-05-01
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2013-06-06
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) Worksite, 315 Lido Blvd, Lido Beach NY - Employee was carrying a 4x8ft piece of plywood up an extension ladder approximately 20ft above the ground below; on or about 4/10/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
331908509 0213600 2012-02-02 2460 BOWEN ROAD, ELMA, NY, 14059
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2012-02-02
Emphasis L: LOCALTARG
Case Closed 2017-01-11

Related Activity

Type Inspection
Activity Nr 190791
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2012-02-23
Current Penalty 1800.0
Initial Penalty 1800.0
Final Order 2012-04-24
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about 2/2/12 at Sylvia's Place Apartment Building located at 2460 Bowen Road, Elma, New York; employees installing drywall were using a relocatable power tap to distribute 120 VAC power to equipment such as, but not limited to, screw guns and spiral saws. The relocatable power tap is not listed for construction use. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2012-02-23
Current Penalty 1800.0
Initial Penalty 1800.0
Final Order 2012-04-24
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 2/2/12 at Sylvia's Place Apartment Building located at 2460 Bowen Road, Elma, New York; employees installing drywall were using 120 VAC power to equipment such as, but not limited to, screw guns and spiral saws. There were damaged cords that also had damaged ground wires and connections. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19260416 B02
Issuance Date 2012-02-23
Current Penalty 1800.0
Initial Penalty 1800.0
Final Order 2012-04-24
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(b)(2): Working spaces, walkways, and similar locations were not kept clear of cords which created a hazard to employees: a) On or about 2/2/12 at Sylvia's Place Apartment Building located at 2460 Bowen Road, Elma, New York; employees installing drywall were using extension cords to distribute 120 VAC power to equipment such as, but not limited to, screw guns and spiral saws. The cords were runs through doorways, cooridors, and work areas creating tripping hazards while employees were carrying and hanging drywall. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01004
Citaton Type Serious
Standard Cited 19260416 E01
Issuance Date 2012-02-23
Current Penalty 1800.0
Initial Penalty 1800.0
Final Order 2012-04-24
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On or about 2/2/12 at Sylvia's Place Apartment Building located at 2460 Bowen Road, Elma, New York; employees installing drywall were using 120 VAC power to equipment such as, but not limited to, screw guns and spiral saws. There were several cords that had damage or improper field repairs. NO ABATEMENT CERTIFICATION REQUIRED