Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-10-08
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2024-08-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2020-03-20 |
Current Penalty |
9446.0 |
Initial Penalty |
9446.0 |
Final Order |
2020-04-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: Location: 7419 15th Ave, Brooklyn, NY On or about 10/8/2019, a) Employee working on ground level was not protected from overhead hazard. Employee working directly under scaffold and was not wearing a hardhat. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 I |
Issuance Date |
2020-03-20 |
Current Penalty |
9445.0 |
Initial Penalty |
9445.0 |
Final Order |
2020-04-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Location: 7419 15th Ave, Brooklyn, NY On or about 10/8/2019, a) Employees worked from a single plank platform assembled on a supported scaffold. The space between the platform and the rear uprights was more than 3 feet wide. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2020-03-20 |
Current Penalty |
9445.0 |
Initial Penalty |
9445.0 |
Final Order |
2020-04-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Location: 7419 15th Ave, Brooklyn, NY On or about 10/8/2019, a) Employees worked from a tubular supported scaffold which was not equipped with safe means of access. Employees climbed the frames and cross braces of the scaffold for access. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 F06 |
Issuance Date |
2020-03-20 |
Current Penalty |
9446.0 |
Initial Penalty |
9446.0 |
Final Order |
2020-04-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6) of power lines. Note: Specify distances as indicated in table in paragraph (f)(6) of this section. Location: 7419 15th Ave, Brooklyn, NY On or about 10/8/2019, a) A supported scaffold was erected and used within close proximity of an electrical service drop of a building. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2020-03-20 |
Current Penalty |
9445.0 |
Initial Penalty |
9445.0 |
Final Order |
2020-04-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 7419 15th Ave, Brooklyn, NY On or about 10/8/2019, a) Employees working from the 4th tier of a supported scaffold were not protected from falling. The rear side of the scaffold platform did not have any guardrail. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260451 H02 II |
Issuance Date |
2020-03-20 |
Current Penalty |
9446.0 |
Initial Penalty |
9446.0 |
Final Order |
2020-04-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below. Location 7419 15th Ave, Brooklyn, NY. On or about 10/8/2019, a) Both the work platform and the material storage platform on the 4th tier of a supported scaffold were not installed with toeboards while an employee was working directly below the scaffold. |
|
|