Search icon

THE LINK GROUP INC.

Company Details

Name: THE LINK GROUP INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 30 Jul 2013 (12 years ago)
Entity Number: 4438347
ZIP code: 11220
County: Kings
Place of Formation: New York
Address: 6204 5TH AVE, BROOKLYN, NY, United States, 11220

Contact Details

Phone +1 212-966-0081

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
ZHI ZENG DOS Process Agent 6204 5TH AVE, BROOKLYN, NY, United States, 11220

Licenses

Number Status Type Date End date
1114046-DCA Inactive Business 2002-07-01 2004-12-31

History

Start date End date Type Value
2023-03-21 2023-04-25 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-04-30 2023-03-21 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-08-31 2022-04-30 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-07-07 2021-08-31 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2013-07-30 2021-07-07 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2013-07-30 2016-07-19 Address 6204 5TH AVE, BROOKLYN, NY, 11220, 4652, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
160719000757 2016-07-19 CERTIFICATE OF CHANGE 2016-07-19
130730000722 2013-07-30 CERTIFICATE OF INCORPORATION 2013-07-30

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2019-09-09 No data 6204 5TH AVE, Brooklyn, BROOKLYN, NY, 11220 Out of Business Inspectorate of the Department of Consumer and Workers' Rights Protection Department of Consumer and Worker Protection No data
2017-11-09 No data 6204 5TH AVE, Brooklyn, BROOKLYN, NY, 11220 Pass Inspectorate of the Department of Consumer and Workers' Rights Protection Department of Consumer and Worker Protection No data
2016-09-09 No data 6204 5TH AVE, Brooklyn, BROOKLYN, NY, 11220 No Violation Issued Inspectorate of the Department of Consumer and Workers' Rights Protection Department of Consumer and Worker Protection No data
2014-05-22 No data 6204 5TH AVE, Brooklyn, BROOKLYN, NY, 11220 No Violation Issued Inspectorate of the Department of Consumer and Workers' Rights Protection Department of Consumer and Worker Protection No data

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
2707668 OL VIO INVOICED 2017-12-08 250 OL - Other Violation
2696580 CL VIO CREDITED 2017-11-20 350 CL - Consumer Law Violation
2696581 OL VIO CREDITED 2017-11-20 250 OL - Other Violation
32462 LL VIO INVOICED 2004-10-12 100 LL - License Violation
556370 RENEWAL INVOICED 2003-01-10 340 Electronics Store Renewal
503694 LICENSE INVOICED 2002-07-01 170 Electronic Store License Fee

Issued Charges

Date Outcome Charge Charge count Counts sellted Counts guilty Counts not guilty
2017-11-09 Pleaded BUSINESS IMPOSES LIMITATIONS ON THE USE OF CREDIT CARDS BUT DOES NOT DISCLOSE THOSE LIMITATIONS. 1 1 No data No data
2017-11-09 Pleaded STORE DID NOT CONSPICUOUSLY DISPLAY THE TOTAL SELLING PRICE, AT POINT OF DISPLAY, FOR ITEM. 2 2 No data No data
2017-11-09 Pleaded REFUND POLICY IS NOT POSTED AT CASH REGISTER/S OR AT THE ENTRANCES. 1 1 No data No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344163670 0215000 2019-07-16 501 MYRTYLE AVE., BROOKLYN, NY, 11205
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2019-07-16
Case Closed 2019-09-20

Related Activity

Type Inspection
Activity Nr 1344395
Safety Yes
343443958 0215000 2018-09-05 501 MYRTLE AVE., BROOKLYN, NY, 11205
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2018-09-07
Case Closed 2024-09-30

Related Activity

Type Inspection
Activity Nr 1344370
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2019-02-04
Abatement Due Date 2019-02-12
Current Penalty 4168.0
Initial Penalty 4168.0
Final Order 2019-04-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) Ground floor: Employees used an electric powered chop saw and an electric powered hand drill to build formwork and stair rails. The tools were connected to extension cords, which were routed to outlet devices in the basement and were not provided with a ground fault circuit interrupter. On or about 09/05/18.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2019-02-04
Abatement Due Date 2019-02-12
Current Penalty 4168.0
Initial Penalty 4168.0
Final Order 2019-04-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. a) Ground floor: Employees used an electric powered chop saw and an electric powered hand drill to build formwork and stair rails. The tools were connected to extension cords, which were routed to outlet devices in the basement and were missing ground pins. On or about 09/05/18.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 B01
Issuance Date 2019-02-04
Abatement Due Date 2019-02-12
Current Penalty 5001.0
Initial Penalty 5001.0
Final Order 2019-04-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. a) Stairway between ground floor and 2nd floor: Employees used a stairway to travel between ground floor and 2nd floor. The treads of pan stairs were not filled or fitted with wood or other solid materials at least to the top edge of each pan to prevent tripping hazard. On or about 09/05/18.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260451 B02
Issuance Date 2019-02-04
Current Penalty 11669.0
Initial Penalty 11669.0
Final Order 2019-04-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) Ground floor, elevator shaft formwork: An employee used one 2" by 4" wood plank supported by the elevator shaft formwork and a metal pole as a scaffold platform for elevation to build the formwork. The scaffold platform which the employee was on while working was not at least 18 inches wide. On or about 08/07/18. The Link Group Inc. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1926.451(b)(2), which was contained in OSHA inspection number 1141454, citation number 1, item number 2 and was affirmed as a final order on 05/25/16, with respect to a workplace located at 312 Fayette Street, Manlius, NY 13104.
Citation ID 03001
Citaton Type Other
Standard Cited 19040039 B02
Issuance Date 2019-02-04
Current Penalty 3789.0
Initial Penalty 3789.0
Final Order 2019-04-04
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.39(b)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation, or the loss of an eye. a) Jobsite: The employer did not report within 24-hours a work-related incident which an employee fell from a scaffold platform and was impaled by a metal pole, and was hospitalized for injuries. The incident occurred on 08/07/18, and OSHA was notified about the incident on 09/04/18. On or about 08/07/18.
341414548 0215800 2016-04-13 312 FAYETTE STREET, MANLIUS, NY, 13104
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-04-13
Emphasis L: FALL, P: FALL
Case Closed 2018-10-22

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2016-05-06
Abatement Due Date 2016-05-18
Current Penalty 1120.0
Initial Penalty 1600.0
Final Order 2016-05-25
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) On or about 4/13/2016, At the jobsite: Employees were utilizing Dewalt grinders without the use of guards. Abatement certification is required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2016-05-06
Abatement Due Date 2016-05-18
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2016-05-25
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide: a) On or about 4/13/2016, At the jobsite: Employees were standing on the midrails and top rails of scissor lifts. Abatement certification is required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260452 W06 I
Issuance Date 2016-05-06
Abatement Due Date 2016-05-18
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2016-05-25
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(w)(6)(i): Employee(s) were allowed to ride on scaffolds when the surface on which the scaffold was moved was not within 3 degrees of level, and/or not free of pits, holes, and obstructions: a) On or about 4/13/2016, At the jobsite: Scissor lifts were driven on a concrete surface which had openings around columns and open pits at the edge of the concrete surface. Abatement certification is required for this item.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2016-05-06
Abatement Due Date 2016-05-18
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2016-05-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: a) On or about 4/13/2016, At the jobsite: Employees performing steel erection work were not utilizing fall protection while exposed to falls of 18 feet. Abatement documentation is required for this item.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260761 B
Issuance Date 2016-05-06
Abatement Due Date 2016-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-05-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.761(b): The employer did not train each employee exposed to a fall hazard in accordance with the requirements of 29 CFR 1926.761: a) On or about 4/13/2016, At the jobsite: Employees performing steel erection work were not provided with training regarding the recognition and avoidance of fall hazards. Abatement certification is required for this item.

Court Cases

Docket Number Nature of Suit Filing Date Disposition
1701325 Marine Contract Actions 2017-03-08 voluntarily
Circuit Second Circuit
Origin original proceeding
Jurisdiction federal question
Jury Demand Neither plaintiff nor defendant demands jury
Demanded Amount 50000
Termination Class Action Missing
Procedural Progress no court action
Nature Of Judgment no monetary award
Judgement missing
Arbitration On Termination Missing
Office 1
Filing Date 2017-03-08
Termination Date 2018-02-12
Section 1330
Status Terminated

Parties

Name HECNY TRANSPORTATION, I,
Role Plaintiff
Name THE LINK GROUP INC.
Role Defendant

Date of last update: 26 Mar 2025

Sources: New York Secretary of State