Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-05-27
|
Emphasis |
L: FALL, L: LOCALTARG, P: FALL
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19260404 B01 II |
Issuance Date |
2021-11-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-12-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were using power tools that were energized with a Generac 5500 generator without GFI protection. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2021-11-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-12-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv):Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were connecting and disconnecting a Makita compressor where the cord to that compressor was pulled free from the tools housing. |
|
Citation ID |
01001C |
Citaton Type |
Other |
Standard Cited |
19260416 E01 |
Issuance Date |
2021-11-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-12-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were connecting and disconnecting a Makita compressor where the cord to that compressor was pulled free from the tools housing, the cord was damaged, and the tape repair to the cord had pulled free. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 II |
Issuance Date |
2021-11-23 |
Current Penalty |
2633.25 |
Initial Penalty |
3511.0 |
Final Order |
2021-12-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were using an interior stairway between the first and second floor where no hand rails were installed. b) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were using an interior stairway between the first and basement floor where no hand rails were installed. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2021-11-23 |
Current Penalty |
1316.25 |
Initial Penalty |
1755.0 |
Final Order |
2021-12-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Lot 48, Water Tower Landing, Water Tower Lane, Central Square, NY 13036, on or about 5/27/21: Workers were using a 5 foot step ladder as a support for a pick and where that ladder was not open with the spreaders locked. |
|
|