Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340823947 | 0213100 | 2015-08-04 | 10 CHATHAM CIRCLE, ALBANY, NY, 12211 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260452 N01 |
Issuance Date | 2015-08-26 |
Current Penalty | 500.0 |
Initial Penalty | 1200.0 |
Final Order | 2015-09-22 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(n)(1): Scaffold platforms were placed higher than the second highest rung or step of the ladder supporting the platform: (a) Left-front side of the building - On or about August 4, 2105, the platform of the step ladder scaffold system was placed on the top step of the left side ladder. An employee was installing Hardie Board siding materials from this system. Elevation of the work plank was approximately 7 feet from the ground. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2015-08-26 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-09-22 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: (a) Left side of the building - On or about August 4, 2105, the employee that was installing fascia materials to the gable end of the building was not wearing a body belt or a harness while performing this work from an articulating boom man lift. Elevation was approximately 18 feet from the ground. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2015-04-16 |
Emphasis | L: LOCALTARG, P: LOCALTARG |
Case Closed | 2015-07-02 |
Related Activity
Type | Inspection |
Activity Nr | 1056110 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260404 B01 II |
Issuance Date | 2015-05-01 |
Current Penalty | 765.0 |
Initial Penalty | 1020.0 |
Final Order | 2015-06-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a) On or about April 16, 2015 at the residential construction jobsite at 4 Cedar Bluff Court, Saratoga Springs, NY 12866 employees of this subcontractor were working at the rear of this location and had plugged in a lead cord that they had connected to house current which did not have ground fault circuit interruption for their personal protection. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260050 D01 |
Issuance Date | 2015-05-01 |
Abatement Due Date | 2015-05-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-06-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.50(d)(1): First aid supplies shall be easily accessible when required: a) On or about April 16, 2015 at the residential construction jobsite at 4 Cedar Bluff Court, Saratoga Spring, NY 12866 employees of this subcontractor were working at this location without being provided with a first aid kit or first aid supplies. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19260150 C01 |
Issuance Date | 2015-05-01 |
Abatement Due Date | 2015-05-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-06-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.150(c)(1): At this job site, fire extinguishers were not provided for each 3,000 square ft. of the protected building area, or major fraction thereof: a) On or about April 16, 2015 at the residential construction jobsite at 4 Cedar Bluff Court, Saratoga Springs, NY 12866 employees of this subcontractor were working at this location without having a fire extinguisher available. |
Date of last update: 26 Mar 2025