Search icon

GUILLERMO FABIAN USA, INC

Company Details

Name: GUILLERMO FABIAN USA, INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 12 Aug 2013 (12 years ago)
Entity Number: 4444257
ZIP code: 11803
County: Nassau
Place of Formation: New York
Address: 169 MAIN PARKWAY WEST, PLAINVIEW, NY, United States, 11803

Shares Details

Shares issued 100

Share Par Value 0.01

Type PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 169 MAIN PARKWAY WEST, PLAINVIEW, NY, United States, 11803

Filings

Filing Number Date Filed Type Effective Date
130812000863 2013-08-12 CERTIFICATE OF INCORPORATION 2013-08-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342601085 0215000 2017-08-30 32 E 74TH STREET, NEW YORK, NY, 10021
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2017-08-30
Case Closed 2017-09-08

Related Activity

Type Inspection
Activity Nr 1220421
Safety Yes
342204211 0215000 2017-03-28 32 EAST 74TH ST, NEW YORK, NY, 10021
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-03-28
Emphasis L: FALL, L: LOCALTARG, P: FALL
Case Closed 2017-08-31

Related Activity

Type Inspection
Activity Nr 1220409
Safety Yes
Type Inspection
Activity Nr 1220414
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 A02 II E
Issuance Date 2017-06-01
Abatement Due Date 2017-06-13
Current Penalty 1629.75
Initial Penalty 2173.0
Final Order 2017-06-01
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a) 3rd Floor in Elevator Shaft - On or about March 28, 2017, employees were exposed to electrical hazards due to a temporary light installed that did not have a protective cover installed.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 II
Issuance Date 2017-06-01
Abatement Due Date 2017-06-13
Current Penalty 2716.5
Initial Penalty 3622.0
Final Order 2017-06-01
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system: a) Instance a) 3rd Floor Elevator Shaft - On or about March 28, 2017, employees were exposed to fall hazards of approximately 35 feet due to the employees working on a false car platform in an elevator shaft without a guardrail system in place.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-06-01
Current Penalty 2716.5
Initial Penalty 3622.0
Final Order 2017-06-01
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 1st Floor Elevator Shaft located near Entrance to Building - On or prior to March 28, 2017, employees were exposed to fall hazards of approximately 15 feet due to the guardrail in place was not fixed or secured in place to ensure that employees were protected from fall down the elevator shaft. The guardrail in place also did not have a midrail to protect employees from fall hazards.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260502 B02
Issuance Date 2017-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-06-01
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: a) 1st Floor Elevator Shaft located near Entrance to Building - On or prior to March 28, 2017, employees were exposed to fall hazards of approximately 15 feet due to the guardrail in place did not have a midrail to protect employees from fall hazards. b) 1st Floor Stairway to Basement - On or about March 28, 2017, employees were exposed to fall hazards of approximately 15 feet due to a guardrail system with mesh that was not secured or fixed adequately to provide protection for workers from falling down the stairwell. c) 3rd Floor Stairway - On or about March 28, 2017, employees were exposed to fall hazards of approximately 10 feet due to a guardrail system with mesh that was not secured or fixed adequately to provide protection for workers from falling down the stairwell.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19260502 B04
Issuance Date 2017-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-06-01
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(4): When the 200 pound (890 N) test load specified in paragraph (b)(3) of this section was applied in a downward direction, the top edge of the guardrail deflected to a height less than 39 inches (1.0 m) above the walking/working level: a) 1st Floor Elevator Shaft located near Entrance to Building - On or prior to March 28, 2017, employees were exposed to fall hazards of approximately 15 feet due to the guardrail not being fixed or secured in place could not withstand 200 pounds of force. b) 1st Floor Stairway to Basement - On or about March 28, 2017, employees were exposed to fall hazards of approximately 15 feet due to a guardrail system with mesh that was not secured or fixed adequately to provide protection for workers from falling down the stairwell. The guardrail not being fixed or secured in place could not withstand 200 pounds of force. c) 3rd Floor Stairway - On or about March 28, 2017, employees were exposed to fall hazards of approximately 10 feet due to a guardrail system with mesh that was not secured or fixed adequately to provide protection for workers from falling down the stairwell. The guardrail not being fixed or secured in place could not withstand 200 pounds of force.
Citation ID 01003D
Citaton Type Serious
Standard Cited 19261052 C12
Issuance Date 2017-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-06-01
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: a) 1st Floor Stairway to Basement - On or about March 28, 2017, employees were exposed to fall hazards of approximately 15 feet due to a guardrail system with mesh that was not secured or fixed adequately to provide protection for workers from falling down the stairwell. b) 3rd Floor Stairway - On or about March 28, 2017, employees were exposed to fall hazards of approximately 10 feet due to a guardrail system with mesh that was not secured or fixed adequately to provide protection for workers from falling down the stairwell.

Date of last update: 26 Mar 2025