Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-06-16
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2015-07-17
|
Related Activity
Type |
Inspection |
Activity Nr |
981505 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
980918 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
981493 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
980924 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
981091 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
980946 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
2014-09-05 |
Abatement Due Date |
2014-09-11 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-09-30 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) Jobsite - On or about May 16, 2014 at 98 Waverly Circle in the North Ridge Hollow residential development in the Town of Colonie safety glasses were not worn when using a nailing gun exposing employees to a hazard of being struck in the eye. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260304 I01 |
Issuance Date |
2014-09-05 |
Current Penalty |
1120.0 |
Initial Penalty |
2400.0 |
Final Order |
2014-09-30 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(i)(1): Each circular hand-fed rip saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: Note: See paragraph (i)(1) of this section for additional requirements for hand-fed ripsaws: a) Jobsite - On or about June 16, 2014 at 98 Waverly Circle in the Town of Colonie a circular hand fed ripsaw did not have a guard for the portion of the saw blade above the table. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260304 F |
Issuance Date |
2014-09-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-09-30 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(f): Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up material or throw it back at the operator: a) Jobsite - On or about June 16, 2014 at 98 Waverly Circle in the Town of Colonie a circular hand fed ripsaw did not have non-kickback fingers or dogs exposing the operator to a struck by hazard. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19260304 F |
Issuance Date |
2014-09-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-09-30 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) Jobsite - On or about June 16, 2014 at 98 Waverly Circle in the Town of Colonie a circular hand fed ripsaw did not have a spreader exposing the operator to a struck by hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260403 D01 |
Issuance Date |
2014-09-05 |
Current Penalty |
1120.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-09-30 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted: a) Jobsite - On or about June 16, 2014 at 98 Waverly Circle in the North Ridge Hollow residential development in the town of Colonie an electrical box that was in use for plugging extension cords into was not mounted as it was intended to be used exposing employees to a shock hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260416 E01 |
Issuance Date |
2014-09-05 |
Current Penalty |
1120.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-09-30 |
Nr Instances |
3 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Jobsite - On or about June 16, 2014 at 98 Waverly Circle, Watervliet NY 12189 employees were exposed to an electric shock hazard because of a worn extension cord that was in use. b. Jobsite - On or about June 16, 2014 at 98 Waverly Circle, Watervliet NY 12189 employees were exposed to an electric shock hazard because of a frayed cord to a portable radio. c. Jobsite - On or about June 16, 2014 at 98 Waverly Circle, Watervliet NY 12189 employees were exposed to an electric shock hazard because of a frayed cord to a table saw. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260502 K03 |
Issuance Date |
2014-09-05 |
Abatement Due Date |
2014-09-11 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-09-30 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(k)(3): A copy of the fall protection plan with all approved changes shall be maintained at the job site. a) On or about May 17, 2014 at 98 Waverly Circle, Watervliet, NY 12189 in the North Ridge Hollow development construction jobsite the fall protection plan was requested but was not available on the jobsite. Employees were exposed to a fall hazard without the fall protection plan on site to follow. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260150 C01 I |
Issuance Date |
2014-09-05 |
Abatement Due Date |
2014-09-11 |
Current Penalty |
400.0 |
Initial Penalty |
400.0 |
Final Order |
2014-09-30 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: a) Jobsite - On or about June 16, 2014 at 98 Waverly Circle in the Town of Colonie the contractor did not have a fire extinguisher available on the jobsite. |
|
|