Search icon

DORROUGH CONSTRUCTION INC

Company Details

Name: DORROUGH CONSTRUCTION INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 12 Nov 2013 (11 years ago)
Entity Number: 4485090
ZIP code: 12118
County: Saratoga
Place of Formation: New York
Address: 77 USHERS ROAD, SUITE 1, MECHANICVILLE, NY, United States, 12118

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
ZACH DORROUGH DOS Process Agent 77 USHERS ROAD, SUITE 1, MECHANICVILLE, NY, United States, 12118

Chief Executive Officer

Name Role Address
WILLIAM Z. DORROUGH Chief Executive Officer 90 WERNER RD, CLIFTON PARK, NY, United States, 12065

History

Start date End date Type Value
2013-11-12 2020-01-08 Address 118 MEYER ROAD, CLIFTON PARK, NY, 12065, USA (Type of address: Service of Process)
2013-11-12 2024-08-12 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
200108060290 2020-01-08 BIENNIAL STATEMENT 2019-11-01
131112010022 2013-11-12 CERTIFICATE OF INCORPORATION 2013-11-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345191951 0215800 2021-03-11 129, 143 AIR CITY BOULEVARD, ROME, NY, 13441
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2021-03-11
Emphasis L: FALL, L: LOCALTARG, P: LOCALTARG
Case Closed 2023-03-29

Related Activity

Type Inspection
Activity Nr 1519204
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 IV
Issuance Date 2021-06-30
Current Penalty 2194.5
Initial Penalty 2926.0
Contest Date 2021-08-18
Final Order 2021-12-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(iv):Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: a) Building 129, center of building, interior, on or about 3-11-21: One employee was working on floor trusses while standing on the mid rail of a mobile elevated work platform, exposing the employee to a fall hazard of 14 feet.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B15
Issuance Date 2021-06-30
Current Penalty 2194.5
Initial Penalty 2926.0
Contest Date 2021-08-18
Final Order 2021-12-17
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(15): Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system: a) Building 143, east side, top deck, on or about 3-11-21: Employees were standing on floor trusses, without fall protection, exposing the employees to a fall hazard of 34 feet to the ground outside of the building. b) Building 129, east side, top deck, on or about 3-11-21: Employees were standing on floor trusses, without fall protection, exposing the employees to a fall hazard of 16 feet to the ground inside of the building. c) Building 129, east side, top deck, on or about 3-11-21: Employees were standing on floor trusses, without fall protection, exposing the employees to a fall hazard of 10 feet to the wood deck below.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260502 D16 III
Issuance Date 2021-06-30
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2021-08-18
Final Order 2021-12-17
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) Building 143, east side, top deck, on or about 3-11-21: One employee was standing on floor trusses, connected to a personal fall arrest system (PFAS) that was rigged with excess slack, such that the employee could fall more than 6 feet before the fall could be arrested, exposing the employees to a fall hazard of up to 34 feet to the ground outside the building and/or 10 feet to the wood deck below b) Building 129, east side, top deck, on or about 3-11-21: One employee was standing on floor trusses, connected to a personal fall arrest system (PFAS) that was rigged with excess slack, such that the employee could fall more than 6 feet before the fall could be arrested, exposing the employees to a fall hazard of 16 feet to the ground inside of the building.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2021-06-30
Current Penalty 2194.5
Initial Penalty 2926.0
Contest Date 2021-08-18
Final Order 2021-12-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) Building 129, center of building, interior, on or about 3-11-21: One employee was working on floor trusses above a scissor lift and exited the floor level by jumping down onto the lift platform, a change in elevation of 65 inches.
345100614 0213100 2020-09-04 1 DUTCHESS AVE., POUGHKEEPSIE, NY, 12601
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2021-01-14
Emphasis L: FALL
Case Closed 2024-12-02

Related Activity

Type Inspection
Activity Nr 1491499
Safety Yes
Type Inspection
Activity Nr 1492729
Safety Yes
Type Inspection
Activity Nr 1495507
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260102 A01
Issuance Date 2021-02-22
Abatement Due Date 2021-02-26
Current Penalty 400.0
Initial Penalty 2809.0
Contest Date 2021-03-19
Final Order 2022-04-01
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee was using eye or face protection when exposed to eye or face hazards from flying particles: a) Building A - On or about September 4, 2020 and at times prior thereto, employees were not wearing eye protection while using pneumatic nail guns during wood framing operations.
Citation ID 01002
Citaton Type Other
Standard Cited 19260453 B02 IV
Issuance Date 2021-02-22
Current Penalty 400.0
Initial Penalty 4213.0
Contest Date 2021-03-19
Final Order 2022-04-01
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(iv):Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: a) Building A - On or about September 9, 2020 and at times prior thereto, an employee working from an aerial lift was standing on the guardrails performing work and using the lift railing to climb to the second floor of the building.
Citation ID 01003
Citaton Type Other
Standard Cited 19260501 B13
Issuance Date 2021-02-22
Abatement Due Date 2021-02-26
Current Penalty 200.0
Initial Penalty 4213.0
Contest Date 2021-03-19
Final Order 2022-04-01
Nr Instances 3
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Building A - On or about September 4, 2020 and at times prior thereto, an employee was exposed to fall hazards while framing the second floor of the building without the use of fall protection. The employee was walking/working along the edge of the unprotected second floor, wearing a harness, but not tied off to an anchor point. b) Building A - On or about September 4, 2020 and at times prior thereto, an employee was exposed to fall hazards while framing the second floor of the building using an inadequate anchor point location which would not limit his fall to less than 6'. The employee was working from the second floor with his self-retracting lanyard anchored below the floors steel support beam. c) Building A - On or about September 4, 2020 and at times prior thereto, an employee was exposed to fall hazards while framing the second floor of the building using an inadequate anchor point location which would not limit his fall to less than 6'. The employee was working from the second floor with his self-retracting lanyard anchored to the aerial lift located below the floor.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2021-02-22
Abatement Due Date 2021-03-04
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2021-03-19
Final Order 2022-04-01
Nr Instances 1
Nr Exposed 13
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a) Building A - On or about September 4, 2020 and at times prior thereto, the employer did not keep a written certification of employee training in fall protection hazards. Employees had received training but it could not be verified through certification.
342367018 0213100 2017-06-01 NEW MOHAWK TOWNHOUSES NEW RIVER CASINO, SCHENECTADY, NY, 12305
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-06-01
Emphasis L: FALL, L: LOCALTARG, P: LOCALTARG
Case Closed 2017-07-07

Related Activity

Type Inspection
Activity Nr 1236697
Safety Yes
342375003 0213100 2017-06-01 DUNKIN DONUTS NEXT TO RIVERS CASINO, SCHENECTADY, NY, 12305
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-06-01
Emphasis N: CTARGET, P: CTARGET
Case Closed 2018-08-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 B01
Issuance Date 2017-06-07
Current Penalty 0.0
Initial Penalty 4155.0
Contest Date 2017-07-10
Final Order 2017-10-18
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(b)(1): Openings in boxes, cabinets, and fittings through which conductors entered were not effectively closed: (a)Jobsite: On or about 5/31/2017, an outlet box located on the scissor lift had unused openings, exposing employees to electrical hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2017-06-07
Current Penalty 0.0
Initial Penalty 4155.0
Contest Date 2017-07-10
Final Order 2017-10-18
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Jobsite: On or about 5/31/2017, there was no strain relief on a flexible cord which was located on a scissor lift on the jobsite. Wires were exposed at the base of the control module exposing employees to electrical hazards.
341578649 0213100 2016-06-23 107 MAIN STREET, SOUTH GLENS FALLS, NY, 12803
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-06-23
Emphasis P: FALL, L: FALL
Case Closed 2016-09-06

Related Activity

Type Inspection
Activity Nr 1175199
Safety Yes
340746692 0213100 2015-07-01 241 S. ALLEN STREET, ALBANY, NY, 12208
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2015-07-01
Emphasis L: FALL
Case Closed 2015-07-01

Related Activity

Type Complaint
Activity Nr 996745
Safety Yes
339949463 0213100 2014-09-12 6 DELAWARE AVE., COHOES, NY, 12047
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2014-09-12
Emphasis L: FALL
Case Closed 2015-12-08

Related Activity

Type Inspection
Activity Nr 994929
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2015-01-07
Abatement Due Date 2015-01-17
Current Penalty 2560.0
Initial Penalty 3200.0
Final Order 2015-01-28
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about September 10, 2014 and at times prior thereto at the job site; employees were exposed to a 9' fall from the roof deck to the floor below without the use of fall protection. The Dorrough Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 940874, citation number 1, item number 1a and was affirmed as a final order on 1-03-2014, with respect to a workplace located at Split Rail Apartments 708 Route 9, Wilton, NY 12831.
339408742 0213100 2013-09-11 708 ROUTE 9 SPLIT RAIL APARTMENTS, WILTON, NY, 12831
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-09-11
Emphasis L: FALL, P: FALL
Case Closed 2014-05-29

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-11-26
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2014-01-03
Nr Instances 4
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): (a) Staging Area, Northeast Side of the Building - on or about September 11, 2013 - a fall hazard of approximately 11 feet, 10 inches from the wall opening to the concrete pad existed on site. Employees were accessing framing materials that were stored adjacent to a 72 inch wide framed door opening. No guardrails were installed on this opening. (b) Cutting Area, Northwest Side of the Building - on or about September 11, 2013 - a fall hazard of approximately 11 feet, 10 inches from the wall opening to the concrete pad existed on site. Employees were cutting framing lumber adjacent to a 72 inch wide framed door opening. No guardrails were installed on this opening. (c) East Side of the Building - on or about September 11, 2013 - a fall hazard of approximately 12 feet, 3 inches existed on site. Employees were cutting framing materials adjacent to a 72 inch wide framed window opening. No guardrails were installed on this opening. (d) Right Side Stairwell Opening - on or about September 11, 2013 - the front section of this opening on the second story floor was not equiped with a guardrail system. The stairs were not installed. Elevation to the first story floor was approximately 11 feet, 10 inches.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2013-11-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-03
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Second Story Floor - on or about September 11, 2013 - the employer did not provide fall protection training to the employees that were performing wood framing.
Citation ID 02001
Citaton Type Other
Standard Cited 19260405 A02 II I
Issuance Date 2013-11-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-03
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: (a) Front of the Building - on or about September 11, 2013 - the electrical extension cord that was used to power the circular saw was not protected from physical damage by vehicular traffic in the parking lot.
Citation ID 02002
Citaton Type Other
Standard Cited 19260416 E01
Issuance Date 2013-11-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-03
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) Front of the Building - on or about September 11, 2013 - the electrical extension cord that was used to power the circular saw had damaged insulation.
338908361 0213100 2013-02-14 1019 WICKER ROAD, TICONDEROGA, NY, 12858
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2013-02-14
Emphasis L: FALL
Case Closed 2014-10-22

Related Activity

Type Complaint
Activity Nr 804856
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2013-03-06
Abatement Due Date 2013-03-12
Current Penalty 1700.0
Initial Penalty 1700.0
Final Order 2013-04-01
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazard(s). (a) Building Roof - on or about February 14, 2013 - 150 installed roof trusses were not installed with sufficient lateral and diagonal bracing to prevent a collapse hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2013-03-06
Current Penalty 867.0
Initial Penalty 867.0
Final Order 2013-04-01
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: (a) Left Side Entrance to the Building - on or about February 14, 2013 - protruding reinforcing steel (rebar) ends on the outside of this building were not properly capped or otherwise protected to prevent impalement hazards to employees that were accessing the work area inside the building through this entrance.
336480389 0213100 2012-09-20 103 BRAOD STREET, WATERFORD, NY, 12188
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-09-20
Emphasis L: LOCALTARG
Case Closed 2012-09-20

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
5154498406 2021-02-07 0248 PPS 77 Ushers Rd Ste 1, Mechanicville, NY, 12118-3403
Loan Status Date 2021-02-25
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 132927
Loan Approval Amount (current) 132927
Undisbursed Amount 0
Franchise Name -
Lender Location ID 188567
Servicing Lender Name Loan Source Incorporated
Servicing Lender Address 353 East 83rd Street Suite 3H, NEW YORK, NY, 10028
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Mechanicville, SARATOGA, NY, 12118-3403
Project Congressional District NY-20
Number of Employees 14
NAICS code 236220
Borrower Race White
Borrower Ethnicity Not Hispanic or Latino
Business Type Corporation
Originating Lender ID 29599
Originating Lender Name Northeast Bank
Originating Lender Address LEWISTON, ME
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 134554.9
Forgiveness Paid Date 2022-05-10
7688467100 2020-04-14 0248 PPP 77 USHERS RD, MECHANICVILLE, NY, 12118-3403
Loan Status Date 2021-06-18
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 143300
Loan Approval Amount (current) 133300
Undisbursed Amount 0
Franchise Name -
Lender Location ID 33209
Servicing Lender Name Berkshire Bank
Servicing Lender Address 99 North St, PITTSFIELD, MA, 01201-5114
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description Unanswered
Project Address MECHANICVILLE, SARATOGA, NY, 12118-3403
Project Congressional District NY-20
Number of Employees 20
NAICS code 236220
Borrower Race White
Borrower Ethnicity Not Hispanic or Latino
Business Type Corporation
Originating Lender ID 33209
Originating Lender Name Berkshire Bank
Originating Lender Address PITTSFIELD, MA
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 134614.74
Forgiveness Paid Date 2021-04-29

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
3041358 Intrastate Non-Hazmat 2019-09-13 15000 2018 2 1 Private(Property)
Legal Name DORROUGH CONSTRUCTION INC
DBA Name -
Physical Address 77 USHERS ROAD SUITE 100, MECHANICVILLE, NY, 12118, US
Mailing Address 77 USHERS ROAD SUITE 100, MECHANICVILLE, NY, 12118, US
Phone (518) 630-5260
Fax -
E-mail ZACHBUILDSBETTER@YAHOO.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 1
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 1
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 3.5
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 1

Inspections

Unique report number of the inspection SPG0261125
State abbreviation that indicates the state the inspector is from NY
The date of the inspection 2023-09-12
ID that indicates the level of inspection Driver-Only
State abbreviation that indicates where the inspection occurred NY
Time weight of the inspection 1
Number of Out-Of-Service violations related to Driver 0
Number of Out-Of-Service violations related to vehicle 0
Number of violations related to Hazardous Materials 0
Total number of Out-Of-Service violations 0
Total number of Out-Of-Service violations related to Hazardous Materials 0
Description of the type of the main unit STRAIGHT TRUCK
Description of the make of the main unit FORD
License plate of the main unit 33703ND
License state of the main unit NY
Vehicle Identification Number of the main unit 1FDXF47P77EB03688
Unsafe Driving BASIC inspection Y
Hours-of-Service Compliance BASIC inspection Y
Driver Fitness BASIC inspection Y
Controlled Substances/Alcohol BASIC inspection Y
Total number of BASIC violations 1
Number of Unsafe Driving BASIC violations 1
Number of Hours-of-Service Compliance BASIC violations 0
Number of Driver Fitness BASIC violations 0
Number of Controlled Substances/Alcohol BASIC violations 0
Number of Vehicle Maintenance BASIC violations 0
Number of Hazardous Materials Compliance BASIC violations 0

Violations

The date of the inspection 2023-09-12
Code of the violation 39216
Name of the BASIC Unsafe Driving
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 7
The time weight that is assigned to a violation 1
The description of a violation Failing to use seat belt while operating a CMV
The description of the violation group Seat Belt
The unit a violation is cited against Driver

Date of last update: 26 Mar 2025

Sources: New York Secretary of State