Filings

Filing Number Date Filed Type Effective Date
140623000217 2014-06-23 CERTIFICATE OF PUBLICATION 2014-06-23
131114000352 2013-11-14 ARTICLES OF ORGANIZATION 2013-11-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339869323 0216000 2014-07-24 1245 PLEASANTVILLE ROAD,, BRIARCLIFF MANOR, NY, 10510
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2014-07-24
Emphasis L: FALL
Case Closed 2019-03-15

Related Activity

Type Complaint
Activity Nr 900094
Safety Yes
Type Inspection
Activity Nr 987154
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-09-02
Abatement Due Date 2014-09-09
Current Penalty 1800.0
Initial Penalty 2800.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports: a) Job Site, 1245 Pleasantville Road, Briarcliff Manor: The single pick platform 12' above the ground used by the employees to apply base coating to the foam, was not fully planked on or about 7/24/2014.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B03
Issuance Date 2014-09-02
Abatement Due Date 2014-09-09
Current Penalty 1800.0
Initial Penalty 2800.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: a) Job Site, 1245 Pleasantville Road: Employees working on a three frame high pipe scaffold were not protected from falling between the work platform and the face of the building, on or about 7/24/14.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2014-09-02
Abatement Due Date 2014-09-09
Current Penalty 1300.0
Initial Penalty 2000.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) Job Site, 1245 Pleasantville Road, Briarcliff Manor: Employees were using cracked planks as a working platform on a pipe scaffold, on or about July 24, 2014.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2014-09-02
Abatement Due Date 2014-09-09
Current Penalty 1800.0
Initial Penalty 2800.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) Job Site, 1245 Pleasantville Road, Briarcliff Manor: Two employees working from a single pick platform approximately 12' high, were not protected from falling to the lower level, or about July 24, 2014.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2014-09-02
Abatement Due Date 2014-09-09
Current Penalty 1300.0
Initial Penalty 2000.0
Final Order 2014-10-03
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) Job site, 1245 Pleasantville Road, Briarcliff Manor: Mid rails were not provided on two sets of pipe scaffolds, three frames high, on or about July 24,2014.

Date of last update: 26 Mar 2025