Search icon

MGS LLC

Company Details

Name: MGS LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 27 Nov 2013 (11 years ago)
Entity Number: 4493662
ZIP code: 11206
County: Kings
Place of Formation: New York
Address: 210 WALLABOUT STREET APT. 2A, BROOKLYN, NY, United States, 11206

DOS Process Agent

Name Role Address
MGS LLC DOS Process Agent 210 WALLABOUT STREET APT. 2A, BROOKLYN, NY, United States, 11206

History

Start date End date Type Value
2013-11-27 2017-08-22 Address 1481 42ND ST, BROOKLYN, NY, 11219, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
181213006346 2018-12-13 BIENNIAL STATEMENT 2017-11-01
170822006103 2017-08-22 BIENNIAL STATEMENT 2015-11-01
131127010112 2013-11-27 ARTICLES OF ORGANIZATION 2013-11-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339916421 0213600 2014-08-25 2400 WALDEN AVENUE, BUFFALO, NY, 14225
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-08-26
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2014-10-22

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2014-09-30
Current Penalty 1338.75
Initial Penalty 1785.0
Final Order 2014-10-06
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a) On or about, 08/25/14 in the tool room, employers were exposed to the unguarded rotating chuck on the lathe machine. NO ABATEMENT REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19100304 B03 I
Issuance Date 2014-09-30
Current Penalty 1338.75
Initial Penalty 1785.0
Final Order 2014-10-06
Nr Instances 1
Nr Exposed 50
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops shall have ground-fault circuit-interrupter protection for personnel. a) On or about, 08/25/14 in the men's bathroom employees were exposed to possible electric shock from a non GFCI receptacle located near the sinks in the bathroom. NO ABATEMENT REQUIRED

Date of last update: 26 Mar 2025

Sources: New York Secretary of State