Search icon

LEDGE ROCK BUILDING & DEVELOPMENT, LLC

Company Details

Name: LEDGE ROCK BUILDING & DEVELOPMENT, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 27 Nov 2013 (11 years ago)
Entity Number: 4493727
ZIP code: 12010
County: Fulton
Place of Formation: New York
Address: 623 MIDLINE ROAD, AMSTERDAM, NY, United States, 12010

DOS Process Agent

Name Role Address
LLC DOS Process Agent 623 MIDLINE ROAD, AMSTERDAM, NY, United States, 12010

Filings

Filing Number Date Filed Type Effective Date
140401000943 2014-04-01 CERTIFICATE OF PUBLICATION 2014-04-01
131127010133 2013-11-27 ARTICLES OF ORGANIZATION 2013-11-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339838393 0213100 2014-06-16 111 DYLAN ROAD, BROADALBIN, NY, 12025
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2014-07-08
Emphasis L: FALL
Case Closed 2014-09-15

Related Activity

Type Inspection
Activity Nr 984010
Safety Yes
Type Inspection
Activity Nr 987251
Safety Yes
Type Referral
Activity Nr 894163
Safety Yes
Type Accident
Activity Nr 894835

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-08-15
Abatement Due Date 2014-08-21
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-09-10
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): (a) Second Story Mezzanine - on or about June 14, 2014 - no guardrails were installed to prevent a fall to the first story and the basement floors. The elevation from the second story mezzanine to the wood first story floor was approximately 10 feet. The elevation to the concrete basement floor from the second story floor was approximately 18 feet, 8 inches.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A02 II
Issuance Date 2014-08-15
Abatement Due Date 2014-08-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-09-10
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used: (a) Jobsite - on or about June 14, 2014 - employees were not trained in the proper procedures for the erection of guardrails that were used as a fall protection system.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260502 B01
Issuance Date 2014-08-15
Abatement Due Date 2014-08-21
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2014-09-10
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: (a) First Story Basement Floor Opening - on or about June 14, 2014 - the height of the top rail of the guardrail system measured between 36 to 37 inches high.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260502 B02
Issuance Date 2014-08-15
Abatement Due Date 2014-08-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-09-10
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: (a) First Story Basement Floor Opening - on or about June 14, 2014 - no midrail was installed on the guardrail system for this opening.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State