Search icon

HYBRID FRAMING & INTERIORS INC.

Company Details

Name: HYBRID FRAMING & INTERIORS INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 05 Dec 2013 (11 years ago)
Entity Number: 4496354
ZIP code: 10954
County: Rockland
Place of Formation: New York
Address: 300 AIRPORT EXECUTIVE PARK, SUITE 305, NANUET, NY, United States, 10954

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 300 AIRPORT EXECUTIVE PARK, SUITE 305, NANUET, NY, United States, 10954

History

Start date End date Type Value
2023-09-18 2023-09-22 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-04-18 2023-09-18 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-03-24 2023-04-18 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-11-16 2023-03-24 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2013-12-05 2021-11-16 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
131205010043 2013-12-05 CERTIFICATE OF INCORPORATION 2013-12-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343584850 0215000 2018-11-07 2807 SNYDER AVE, BROOKLYN, NY, 11226
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-11-07
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2019-04-12
341487585 0215000 2016-04-01 1229 45TH ST,, BROOKLYN, NY, 11203
Inspection Type Unprog Other
Scope Complete
Safety/Health Safety
Close Conference 2016-05-26
Emphasis L: FALL
Case Closed 2018-02-23

Related Activity

Type Inspection
Activity Nr 1139763
Safety Yes
Type Inspection
Activity Nr 1148849
Safety Yes
Type Inspection
Activity Nr 1148418
Safety Yes

Violation Items

Citation ID 01003A
Citaton Type Serious
Standard Cited 19260454 A03
Issuance Date 2016-09-30
Abatement Due Date 2016-10-20
Current Penalty 9350.0
Initial Penalty 12471.0
Contest Date 2016-10-25
Final Order 2017-06-07
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a)(3): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training did not include the proper use of the scaffold, and the proper handling of materials on the scaffold. a) Employees were not trained on the proper handling of materials and use of temporary platforms erected in the elevator shaft. Location : 1229 45th Street, Brooklyn N.Y. On or about 4/1/2016 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260454 A04
Issuance Date 2016-09-30
Abatement Due Date 2016-10-20
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-10-25
Final Order 2017-06-07
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a)(4): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training did not include the maximum intended load and the load-carrying capacities of the scaffolds used. a) Employees were not trained on the capabilities of the maximum load-carrying capacity of the temporary platforms erected in the elevator shaft. Location : 1229 45th Street, Brooklyn N.Y. On or about 4/1/2016 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 A06
Issuance Date 2016-09-30
Current Penalty 9350.0
Initial Penalty 12471.0
Contest Date 2016-10-25
Final Order 2017-06-07
Nr Instances 4
Nr Exposed 4
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(6): The employer did not ensure that scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design: a) Four temporary floor/platforms were constructed in the elevator shaft by the employer were no designed by a qualified person. Location: 1229 45th Street, Brooklyn N.Y. On or about 4/1/2016 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2016-09-30
Abatement Due Date 2016-10-20
Current Penalty 0.0
Initial Penalty 12471.0
Contest Date 2016-10-25
Final Order 2017-06-07
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) Temporary platforms erected in the elevator shaft were not erected by a trained experienced employee under the supervision of a competent person. Location : 1229 45th Street, Brooklyn N.Y. On or about 4/1/2016 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
340049204 0215000 2014-10-30 155 W 126TH STREET, NEW YORK, NY, 10027
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-10-30
Emphasis L: FALL
Case Closed 2016-01-20

Related Activity

Type Complaint
Activity Nr 918627
Safety Yes

Violation Items

Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-12-19
Current Penalty 1500.0
Initial Penalty 2400.0
Final Order 2015-01-29
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about October 30, 2014, and again on October 31, 2014 A). Employees entering, exiting and working on the first floor of the project were exposed to fall hazards because the flooring materials had been removed and exposed the open floor joists to the basement below. Employees were not protected from falling into the basement by any means of Personal Fall Protection, Guardrails, or Safety Netting.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261052 B01
Issuance Date 2014-12-19
Abatement Due Date 2015-01-02
Current Penalty 1500.0
Initial Penalty 2400.0
Final Order 2015-01-29
Nr Instances 24
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan.Temporary treads and landings used for pan stairs that were to be filled in with concrete or other solid material at a later date were worn below the level of the top edge of the pan. On or about October 30, 2014 and October 31, 2014 Location: 155 West 126th Street, New York, NY every stair well throughout the project. Employees were traversing throughout the project using stairwells and were exposed to trip and fall hazards because the stair landing pans were not filled in with a solid material and the material used to fill stair treads had been worn down below the top lip of the tread pan.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2014-12-19
Abatement Due Date 2015-01-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-29
Nr Instances 3
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a handrail system along each unprotected side or edge: On or about October 30, 2014, and again on October 31, 2014. Location: 155 West 126th Street, New York, NY a). Employees working on site traversed the west stairs from roof top to street level numerous times daily to complete their work. Employees were exposed to fall hazards because the stair systems was not equipped with a handrail system along each unprotected side or edge of the stairs.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19261052 C04
Issuance Date 2014-12-19
Abatement Due Date 2015-01-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-29
Nr Instances 3
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(4): Employer did not ensure Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were provided between the top rail of the stair rail system and the stairway steps: On or about October 30, 2014, and again on October 31, 2014. Location; 155 West 126th Street, New York, NY West structure fourth floor stairway. a). Employees utilizing stairs to traverse through the project from ground level to the roof, were not protected from falls off the stairs because the stairwells were not protected with midrails, screens, mesh, or intermediate vertical members.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260404 B01 II
Issuance Date 2014-12-19
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2015-01-29
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. On or about October 30, 2014 and October 31, 2014 Location: 155 West 126th Street, NY NY, 4th floor east side of stairs. Employees were utilizing a temporary electrical outlet box to energize portable power tools, that was not protected from ground fault electrical shorts, because the temporary wiring system was not protected by a ground fault circuit interrupter.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260405 J01 II
Issuance Date 2014-12-19
Current Penalty 0.0
Initial Penalty 1600.0
Final Order 2015-01-29
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported: On or about October 30, 2014 LOCATION: 155 West 126th Street, New York, NY, west stairway on fourth floor. a). Employees were using a temporary 1900 type, 4 inch square electric outlet box to energize power tools. The 1900 box was not properly secured to a permanent location.