Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 D01 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
1315.2 |
Initial Penalty |
1705.0 |
Final Order |
2019-09-22 |
Nr Instances |
3 |
Nr Exposed |
8 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(d)(1): Walking-working surfaces were not maintained in a safe condition: a) On or about 4/19/2019, Main Warehouse: The East overhead door/ entrance ramp was not maintained in a safe condition in that there was a seven inch drop which powered industrial trucks were required to travel over. b) On or about 4/19/2019, East Warehouse: The North entrance ramp was not maintained in a safe condition in that there was a four inch lip/ drop which powered industrial trucks were required to travel over. c) On or about 4/19/2019, Main Warehouse: There was a piece of steel protruding from the floor in the travel path by the front door. Abatement certification is required for these items. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2019-06-26 |
Current Penalty |
1315.2 |
Initial Penalty |
2842.0 |
Final Order |
2019-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) On or about 4/19/2019, East Warehouse: An approximately 200 foot long open sided floor was not provided with fall protection. Employees exposed to falls of 15 feet. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
1315.2 |
Initial Penalty |
1705.0 |
Final Order |
2019-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) On or about 4/19/2019, West Warehouse: The knob was missing from an emergency exit door. Abatement certification is required for this item. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100037 A03 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-09-22 |
Nr Instances |
3 |
Nr Exposed |
8 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(3): Exit routes were not free and unobstructed. Materials or equipment were placed, either permanently or temporarily, within the exit route. The exit access went through a room that could be locked, to reach an exit or exit discharge: a) On or about 4/19/2019, West Warehouse: An emergency exit located on the East wall of the warehouse was partially obstructed by items in storage. b) On or about 4/19/2019, Main Warehouse: An emergency exit located on the West end of the North wall was blocked by material in storage. c) On or about 4/19/2019, Main Warehouse: An emergency exit located on the East end of the North wall was blocked by material in totes and on the floor. Abatement certification is required for these items. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100037 B01 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
1315.2 |
Initial Penalty |
2273.0 |
Final Order |
2019-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route. a) On or about 4/19/2019, Main Warehouse: All of the exit ways and travel ways used as exits were not provided with adequate lighting. Abatement certification is required for this item. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100178 H02 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(h)(2): Where general lighting is less than 2 lumens per square foot, auxiliary directional lighting shall be provided on the truck: a) On or about 4/19/2019, Main Warehouse: There was less than 2 lumens of light inside of the main warehouse and access tunnel to West warehouse. No auxiliary lighting was present on the rear of powered industrial trucks. Abatement certification is required for this item. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100176 B |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
1315.2 |
Initial Penalty |
2273.0 |
Final Order |
2019-09-22 |
Nr Instances |
2 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) On or about 4/19/2019, Main Warehouse: Material stored in the tunnel between warehouses was partially collapsed and not stable. b) On or about 4/19/2019, East Warehouse: Used Beverage Container (UBC) blocks were partially collapsed and not stable. Abatement certification is required for this item. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
0.0 |
Initial Penalty |
2273.0 |
Final Order |
2019-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1): The employer did not ensure that each power industrial truck operator was competent to operate a power industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in paragraph (l): a) On or about 4/19/2019, Throughout the facility: Employees required to operate powered industrial trucks were not provided with training prior to operating various powered industrial trucks on site. Abatement certification is required for this item. |
|
Citation ID |
01007A |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
1315.2 |
Initial Penalty |
2273.0 |
Final Order |
2019-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition: a) On or about 4/19/2019, Throughout the facility: A Cat LP forktruck with an inoperable emergency brake and a broken LP retention system was not taken out of service. Abatement certification is required for this item. |
|
Citation ID |
01007B |
Citaton Type |
Serious |
Standard Cited |
19100178 Q07 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(q)(7): Industrial trucks were not examined before use: a) On or about 4/19/2019, Throughout the facility: Powered Industrial Trucks were provided with a daily inspection, prior to use. Abatement certification is required for this item. |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100303 B01 |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
1315.2 |
Initial Penalty |
2273.0 |
Final Order |
2019-09-22 |
Nr Instances |
3 |
Nr Exposed |
8 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) On or about 4/19/2019, Main Warehouse: Electrical outlets were not mounted, and were suspended by conduit. b) On or about 4/19/2019, Main Warehouse: Electrical outlets were buried in shredded aluminum. c) On or about 4/19/2019, Main Warehouse: An electrical distribution box was not mounted to a structure. Abatement certification is required for these items. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100141 D02 II |
Issuance Date |
2019-06-26 |
Abatement Due Date |
2019-07-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-09-22 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: a) On or about 4/19/2019, Main Warehouse: The lavatory was not provided with hot or tepid water. Abatement certification is required for this item. |
|