Name: | ALL CITY CONSTRUCTION NY INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 09 Jan 2014 (11 years ago) |
Entity Number: | 4510878 |
ZIP code: | 10002 |
County: | New York |
Place of Formation: | New York |
Address: | 275 BROOME STREET APT. 4, NEW YORK, NY, United States, 10002 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 275 BROOME STREET APT. 4, NEW YORK, NY, United States, 10002 |
Start date | End date | Type | Value |
---|---|---|---|
2023-04-28 | 2023-05-05 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2014-01-09 | 2023-04-28 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
140109000340 | 2014-01-09 | CERTIFICATE OF INCORPORATION | 2014-01-09 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344549381 | 0215000 | 2020-01-08 | 1437 74TH ST., BROOKLYN, NY, 11228 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260300 B01 |
Issuance Date | 2020-04-09 |
Current Penalty | 2100.0 |
Initial Penalty | 3856.0 |
Final Order | 2020-04-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) 1st floor, bathroom: An employee used an electric powered angle grinder to cut plastic strips for shower installation. The angle grinder was designed to accommodate a guard for the cutting wheel, and was not equipped with such guard when in use. On or about 01/08/2020. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260404 B01 I |
Issuance Date | 2020-04-09 |
Current Penalty | 2100.0 |
Initial Penalty | 3856.0 |
Final Order | 2020-04-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) 1st floor: An employee used electric powered tools to do framing installation. The tools were connected to extension cords, which were routed to nearby outlet devices and were not provided with ground fault circuit interrupter. On or about 01/08/2020. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260405 J01 II |
Issuance Date | 2020-04-09 |
Current Penalty | 2100.0 |
Initial Penalty | 3856.0 |
Final Order | 2020-04-24 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported. a) Throughout entire site, 1st and 2nd floor: Energized electrical receptacles and light switches were not securely supported. They were left hanging by energized wires attached to the devices. On or about 01/08/2020. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2020-04-09 |
Current Penalty | 3700.0 |
Initial Penalty | 5398.0 |
Final Order | 2020-04-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. a) 2nd floor balcony: An employee was working at the edge of the 2nd floor balcony without fall protection. He was exposed to falling approximately 12 feet to ground. On or about 01/08/2020. |
Date of last update: 26 Mar 2025
Sources: New York Secretary of State