Search icon

ISLAND FRAMERS, INC.

Company Details

Name: ISLAND FRAMERS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 21 Jan 2014 (11 years ago)
Entity Number: 4516332
ZIP code: 11763
County: Suffolk
Place of Formation: New York
Address: 29 NEVADA AVENUE, MEDFORD, NY, United States, 11763

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
XAVIER RIVERA Chief Executive Officer 29 NEVADA AVENUE, MEDFORD, NY, United States, 11763

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 29 NEVADA AVENUE, MEDFORD, NY, United States, 11763

History

Start date End date Type Value
2014-01-21 2024-11-01 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2014-01-21 2024-11-01 Address 29 NEVADA AVENUE, MEDFORD, NY, 11763, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
241101037752 2024-11-01 BIENNIAL STATEMENT 2024-11-01
140121000459 2014-01-21 CERTIFICATE OF INCORPORATION 2014-01-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346887193 0214700 2023-08-04 542 TREMONT PLACE, EAST MEADOW, NY, 11003
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2023-08-04
Emphasis N: FALL

Related Activity

Type Inspection
Activity Nr 1688711
Safety Yes
Type Complaint
Activity Nr 2064013
Safety Yes
Type Inspection
Activity Nr 1688714
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-01-09
Abatement Due Date 2024-01-16
Current Penalty 2511.75
Initial Penalty 3349.0
Final Order 2024-02-07
Nr Instances 3
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 542 Tremont Place, East Meadow, NY, 11003 South Building- Employees were installing ceiling joists on the 2nd story of a new residential private dwelling approximately 18 feet above the ground and were not protected from falling; on or about 8/4/2023. b) Worksite, 542 Tremont Place, East Meadow, NY, 11003 North Building- Employees were installing header joists on the edge of the structure where the second level floor of a new residential private dwelling approximately 9 feet above the ground and were not protected from falling; on or about 8/4/2023. c) Worksite, 542 Tremont Place, East Meadow, NY, 11003 North Building- Employees were measuring and marking vertical stud locations on the 2nd floor of a new residential private dwelling approximately 9 feet above the ground and were not protected from falling; on or about 8/7/2023. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-01-09
Current Penalty 2511.75
Initial Penalty 3349.0
Final Order 2024-02-07
Nr Instances 2
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Worksite 542 Tremont Place, East Meadow, NY, 11003- Employees were using a 24-Foot Louisville extension ladder to gain access to the top of the first level of the north building, approximately 9 ft above the ground. The ladder did not extend 3 feet above the landing; on or about 8/4/2023. b) Worksite 542 Tremont Place, East Meadow, NY, 11003- Employees were using a 24-foot Louisville extension ladder to gain access to the top of the first level and did not extend 3 feet above the landing; on or about 8/7/2023 Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
339740706 0214700 2014-04-24 251 GLEN COVE ROAD, OLD WESTBURY, NY, 11568
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-04-24
Emphasis L: FALL, P: FALL
Case Closed 2014-07-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-05-06
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2014-05-14
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) worksite - Employees working directly under ongoing framing activities were not using head protection; on or about 04/24/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2014-05-06
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2014-05-14
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite - An employee framing a doghouse dormer approximately 24 feet above the ground from an elevated work platform was not protected from falling; on or about 04/24/14. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-05-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-14
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) worksite - Employees framing a doghouse dormer from an approximate 8-12 pitch roof approximately 24 feet above the ground were not wearing fall protection; on or about 04/24/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-05-06
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-05-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) worksite - Employees were using an unsecured ladder to access an upper landing. The ladder side rails were approximately 8 inches above the upper landing; on or about 04/24/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State